G6-EH1P(3-10)K-L-PLUS
3 – 10 kWSingle-phaseIP66
View details
MIN 3000-11400TL-XH-US
Hybrid inverter · Split-phase · 3 – 11.4 kW
3 – 11.4 kWSplit-phaseIP65
Price on request
3 – 11.4 kWRated power
Split-phasePhase
2 – 4MPPT trackers
98 – 98.5 %Max. efficiency
Technical data
| MIN 3000TL-XH-US | MIN 3800TL-XH-US | MIN 5000TL-XH-US | MIN 6000TL-XH-US | MIN 7600TL-XH-US | MIN 8200TL-XH-US | MIN 9000TL-XH-US | MIN 10000TL-XH-US | MIN 11400TL-XH-US | |
|---|---|---|---|---|---|---|---|---|---|
| PV input | |||||||||
| Max. PV input power (W) | 6000 | 7600 | 10000 | 12000 | 15200 | 16400 | 18000 | 20000 | 22800 |
| Max. PV input voltage (V) | 600 | ||||||||
| Rated PV input voltage (V) | 360 | ||||||||
| MPPT voltage range (V) | 50 – 550 | ||||||||
| Full-load voltage range (V) | 120 – 500 | 150 – 500 | 200 – 500 | 160 – 500 | 200 – 500 | 160 – 500 | 180 – 500 | 200 – 500 | 220 – 500 |
| Start-up voltage (V) | 80 | ||||||||
| Max. input current per MPPT (A) | 13.5 | ||||||||
| Max. short-circuit current per MPPT (A) | 16.9 | ||||||||
| Number of MPPT trackers | 2 | 2 | 2 | 3 | 3 | 4 | 4 | 4 | 4 |
| PV strings per MPPT | 2 | ||||||||
| DC/AC ratio | 2 | ||||||||
| AC output | |||||||||
| Rated output power (W) | 3000 | 3800 | 5000 | 6000 | 7600 | 8200 | 9000 | 10000 | 11400 |
| AC nominal power @208 V (W) | 2600 | 3290 | 4330 | 5200 | 6580 | 7100 | 7800 | 8660 | 9880 |
| Max. apparent power (VA) | 3000 | 3800 | 5000 | 6000 | 7600 | 8200 | 9000 | 10000 | 11400 |
| Rated AC voltage (V) | 240 | ||||||||
| Nominal AC voltage options (V) | 208 / 240 | ||||||||
| AC voltage range (@208 V / @240 V) (V) | 183-229 / 211-264 | ||||||||
| Phase | Split-phase | ||||||||
| Rated AC frequency (Hz) | 50/60 | ||||||||
| AC grid frequency range (Hz) | 45 – 65 | ||||||||
| Max. AC output current (A) | 12.5 | 16 | 21 | 25 | 32 | 35 | 38 | 42 | 48 |
| Max. output overcurrent protection (A) | 20 | 20 | 30 | 40 | 40 | 63 | 63 | 63 | 63 |
| Power factor | >0.99 at nominal power; adjustable 0.8 leading to 0.8 lagging | ||||||||
| Total harmonic distortion (THDi) (%) | <3 | ||||||||
| AC grid connection type | L1 / L2 / N / PE | ||||||||
| Backup output power (W) | 3000 | 3800 | 5000 | 6000 | 7600 | 8200 | 9000 | 10000 | 11400 |
| Backup max. AC power output (VA) | 4700 | 6000 | 7900 | 9400 | 12000 | 12900 | 14200 | 15800 | 18000 |
| Backup nominal AC voltage (V) | 240 | ||||||||
| Backup max. output current (A) | 20 | 25 | 33 | 40 | 50 | 54 | 59 | 66 | 75 |
| Backup output THD | 2% (linear load); 5% (non-linear load) | ||||||||
| AC port, V2 inverter | 2 AC ports (1 on-grid, 1 backup/EPS); compatible with an automatic transfer switch for partial-home backup | ||||||||
| AC port, V3 inverter | 1 AC port (on-grid); compatible with the dedicated whole-home backup unit | ||||||||
| Max. motor load supported (HP) | 5.5 | ||||||||
| Battery | |||||||||
| Battery type | Lithium iron phosphate (LFP) | ||||||||
| Battery voltage range (V) | 360 – 550 | ||||||||
| Nominal battery voltage (V) | 400 | ||||||||
| Max. charge current (A) | 8.9 | 11.1 | 14.4 | 17.2 | 21.7 | 23.6 | 25.8 | 28.6 | 32.5 |
| Max. discharge current (A) | 8.9 | 11.1 | 14.4 | 17.2 | 21.7 | 23.6 | 25.8 | 28.6 | 32.5 |
| Max. charge power (W) | 3200 | 4000 | 5200 | 6200 | 7800 | 8500 | 9300 | 10300 | 11700 |
| Max. discharge power (W) | 3200 | 4000 | 5200 | 6200 | 7800 | 8500 | 9300 | 10300 | 11700 |
| Efficiency | |||||||||
| Max. efficiency (%) | 98 | 98 | 98.2 | 98.4 | 98.4 | 98.3 | 98.3 | 98.3 | 98.5 |
| CEC efficiency (%) | 97 | 97 | 97.5 | 97 | 97.5 | 97.5 | 97.5 | 97.5 | 98 |
| CEC efficiency @208 V (%) | 96.5 | 97.0 | 97.5 | 97.0 | 97.0 | 97.5 | 97.5 | 97.5 | 97.5 |
| Protection | |||||||||
| Protection functions | DC reverse-polarity protection; DC switch; DC surge protection (Type II); Insulation resistance monitoring; AC surge protection (Type III); AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection | ||||||||
| General data | |||||||||
| Dimensions (W x H x D) (mm) | 400 × 569 × 170.5 | 400 × 569 × 170.5 | 400 × 569 × 170.5 | 400 × 569 × 170.5 | 400 × 569 × 170.5 | 400 × 638 × 187 | 400 × 638 × 187 | 400 × 638 × 187 | 400 × 638 × 187 |
| Weight (kg) | 14.65 | 14.65 | 14.65 | 14.65 | 14.65 | 20.5 | 20.5 | 20.5 | 20.5 |
| Ingress protection (IP rating) | IP65 | ||||||||
| NEMA enclosure rating | 4X | ||||||||
| Operating temperature range (°C) | −25 – 60 | ||||||||
| Power derating above (°C) | 45 | ||||||||
| Relative humidity (%) | 0 – 95 | ||||||||
| Max. operating altitude (m) | 3000 | ||||||||
| Night-time power consumption (W) | <5 | ||||||||
| Cooling | Natural convection | ||||||||
| Revenue grade meter | ANSI C12.20 (0.5% accuracy) | ||||||||
| Warranty (years) | 10 | ||||||||
| Communication | |||||||||
| Communication interfaces | RS485; Wi-Fi (optional); 4G (optional) | ||||||||
| Certifications | |||||||||
| Certifications and standards | UL 1741; UL 1741SA; UL 1741SB; UL 1699B; IEEE 1547; IEEE 1547.1; HECO SRD-IEEE-1547.1; CSA C22.2 No. 107.1; UL 9540; FCC Part 15 Class B | ||||||||
| Grid codes | UL 1741 SA/SB; CA Rule 21; HECO | ||||||||
| Rapid shutdown (RSD) compliance | UL 1741 PVRSS; NEC 2020 690.12 | ||||||||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
G6-EH1P(3-10)K-L-PLUS
3 – 10 kWSingle-phaseIP66
View details
MOD 3-15KTL3-HU
3 – 15 kWThree-phaseIP66
View details
MOD 3000-10000TL3-XH
3 – 10 kWThree-phaseIP66
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.