S6-EH1P(3-6)K-L-EU
3 – 6 kWSingle-phaseIP66
View details
S6-EH3P(3-12)K-H
Hybrid inverter · Three-phase · 3 – 12 kW
3 – 12 kWThree-phaseIP66
Price on request
3 – 12 kWRated power
Three-phasePhase
2 – 4MPPT trackers
95.5 – 97.9 %Max. efficiency
Technical data
| S6-EH3P 3K-EU | S6-EH3P 4K-EU | S6-EH3P 5K-EU | S6-EH3P 6K-EU | S6-EH3P 8K-EU | S6-EH3P 10K-EU | S6-EH3P 12K | S6-EH3P 5K2 | S6-EH3P 6K2 | S6-EH3P 8K2 | S6-EH3P 10K2 | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| PV input | |||||||||||
| Max. PV input power (W) | 6000 | 8000 | 10000 | 12000 | 16000 | 20000 | 24000 | 10000 | 12000 | 16000 | 20000 |
| Max. usable PV input power (W) | 4800 | 6400 | 8000 | 9600 | 12800 | 16000 | 19200 | 8000 | 9600 | 12800 | 16000 |
| Max. PV input voltage (V) | 1000 | ||||||||||
| Rated PV input voltage (V) | 600 | ||||||||||
| Start-up voltage (V) | 160 | ||||||||||
| MPPT voltage range (V) | 200 – 850 | ||||||||||
| Max. input current per MPPT (A) | 16 | 16 | 16 | 16 | 16 | 16 | 21 | 16 | 16 | 16 | 16 |
| Max. short-circuit current per MPPT (A) | 24 | 24 | 24 | 24 | 24 | 24 | 31.5 | 24 | 24 | 24 | 24 |
| Number of MPPT trackers | 2 | 2 | 3 | 3 | 4 | 4 | 4 | 2 | 2 | 2 | 2 |
| Max. number of PV input strings | 2 | 2 | 3 | 3 | 4 | 4 | 4 | 2 | 2 | 2 | 2 |
| AC output | |||||||||||
| Rated output power (W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 5000 | 6000 | 8000 | 10000 |
| Max. apparent power (VA) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 5000 | 6000 | 8000 | 10000 |
| Rated AC voltage (V) | 400 | ||||||||||
| Rated AC output current (A) | 4.3 | 5.8 | 7.2 | 8.7 | 11.5 | 14.4 | 17.3 | 7.2 | 8.7 | 11.5 | 14.4 |
| Phase | Three-phase | ||||||||||
| Rated AC frequency (Hz) | 50/60 | ||||||||||
| Max. AC output current (A) | 4.3 | 5.8 | 7.2 | 8.7 | 11.5 | 14.4 | 17.3 | 7.2 | 8.7 | 11.5 | 14.4 |
| Power factor | > 0.99 (0.8 leading to 0.8 lagging) | ||||||||||
| Total harmonic distortion (THDi) (%) | <3 | ||||||||||
| AC input voltage range (grid side, 380 V / 400 V) (V) | 304-437 / 320-460 | ||||||||||
| Max. AC input current (grid side, 380 V / 400 V) (A) | 6.8 / 6.5 | 9.1 / 8.7 | 11.4 / 10.9 | 13.6 / 13.0 | 18.2 / 17.4 | 22.7 / 21.7 | 27.3 / 26.0 | 11.4 / 10.9 | 13.6 / 13.0 | 18.2 / 17.4 | 22.7 / 21.7 |
| Rated AC input frequency (grid side) (Hz) | 50 / 60 | ||||||||||
| AC input frequency range (grid side) (Hz) | 45-55 / 55-65 | ||||||||||
| Backup output power (W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 5000 | 6000 | 8000 | 10000 |
| Peak (surge) power (W) | 4800 | 6400 | 8000 | 9600 | 12800 | 16000 | 19200 | 8000 | 9600 | 12800 | 16000 |
| Off-grid overload duration (s) | 60 | ||||||||||
| Grid / off-grid switchover time (ms) | <10 | ||||||||||
| Rated output voltage, off-grid side (V) | 380 / 400 | ||||||||||
| Rated frequency, off-grid side (Hz) | 50 / 60 | ||||||||||
| Rated output current, off-grid side (380 V / 400 V) (A) | 4.6 / 4.3 | 6.1 / 5.8 | 7.6 / 7.2 | 9.1 / 8.7 | 12.2 / 11.5 | 15.2 / 14.4 | 18.2 / 17.3 | 7.6 / 7.2 | 9.1 / 8.7 | 12.2 / 11.5 | 15.2 / 14.4 |
| Total voltage harmonic distortion (THDv), off-grid side (%) | <2 | <2 | <2 | <2 | <2 | <2 | <3 | <2 | <2 | <2 | <2 |
| Generator input | Yes | ||||||||||
| Max. parallel units | 6 | ||||||||||
| Battery | |||||||||||
| Battery type | Lithium battery | ||||||||||
| Battery voltage range (V) | 120 – 600 | 120 – 600 | 120 – 600 | 120 – 600 | 120 – 600 | 120 – 600 | 120 – 700 | 120 – 600 | 120 – 600 | 120 – 600 | 120 – 600 |
| Max. charge power (W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 5000 | 6000 | 8000 | 10000 |
| Max. discharge power (W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 5000 | 6000 | 8000 | 10000 |
| Max. charge current (A) | 25 | 25 | 25 | 25 | 50 | 50 | 50 | 25 | 25 | 50 | 50 |
| Max. discharge current (A) | 25 | 25 | 25 | 25 | 50 | 50 | 50 | 25 | 25 | 50 | 50 |
| Battery communication | CAN / RS485 | ||||||||||
| Efficiency | |||||||||||
| Max. efficiency (%) | 95.5 | 96 | 96.5 | 97 | 97.5 | 97.9 | 97.85 | 96.5 | 97 | 97.5 | 97.9 |
| European efficiency (%) | 95.51 | 96.03 | 96.77 | 97.1 | 97.41 | 97.51 | 97.51 | 96.77 | 97.1 | 97.41 | 97.51 |
| Max. PV charging efficiency (%) | 95.96 | 96.57 | 98.37 | 98.45 | 98.22 | 98.31 | 98.31 | 98.37 | 98.45 | 98.22 | 98.31 |
| Max. battery charge / discharge efficiency (%) | 97.04 | 97.29 | 97.32 | 97.34 | 97.50 | 97.50 | 97.50 | 97.32 | 97.34 | 97.50 | 97.50 |
| Protection | |||||||||||
| Protection functions | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; Surge protection (DC Type II / AC Type II optional); DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; Surge protection (DC Type II / AC Type II optional); DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; Surge protection (DC Type II / AC Type II optional); DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; Surge protection (DC Type II / AC Type II optional); DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; Surge protection (DC Type II / AC Type II optional); DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; Surge protection (DC Type II / AC Type II optional); DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; Surge protection (DC Type II / AC Type II optional); Integrated DC switch; DC reverse polarity protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; DC arc fault protection (optional); Integrated DC switch; DC reverse polarity protection; PV overvoltage protection; Battery reverse polarity protection |
| General data | |||||||||||
| Dimensions (W x H x D) (mm) | 600 × 500 × 210 | 600 × 500 × 210 | 600 × 500 × 210 | 600 × 500 × 210 | 600 × 500 × 230 | 600 × 500 × 230 | 563 × 412 × 230 | 600 × 500 × 210 | 600 × 500 × 210 | 600 × 500 × 230 | 600 × 500 × 230 |
| Weight (kg) | 26.4 | 26.4 | 27.6 | 27.6 | 30.2 | 30.2 | 34.5 | 27.6 | 27.6 | 30.2 | 30.2 |
| Topology | Transformerless | ||||||||||
| Night-time power consumption (W) | <25 | ||||||||||
| Operating temperature range (°C) | −25 – 60 | ||||||||||
| Relative humidity (%) | 0 – 100 | ||||||||||
| Ingress protection (IP rating) | IP66 | ||||||||||
| Noise level (dB) | <46.9 | ||||||||||
| Cooling | Natural convection | ||||||||||
| Max. operating altitude (m) | 4000 | ||||||||||
| Max. single-phase load capacity | 50% of rated power | ||||||||||
| Max. three-phase unbalanced load capacity (%) | 100 | 100 | 100 | 100 | 100 | 100 | – | 100 | 100 | 100 | 100 |
| PV connector | MC4 | ||||||||||
| Battery connector | Quick connector | ||||||||||
| AC connector | Quick connector | ||||||||||
| Communication | |||||||||||
| Display | LED indicators, Bluetooth + APP | ||||||||||
| Communication interfaces | CAN; RS485; Wi-Fi (optional); Cellular (optional); LAN (optional) | ||||||||||
| Certifications | |||||||||||
| Certifications and standards | IEC/EN 62109-1/-2; IEC/EN 61000-6-1/-3 | ||||||||||
| Grid codes | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA; EK18 | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA | G98 or G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA |
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
S6-EH1P(3-6)K-L-EU
3 – 6 kWSingle-phaseIP66
View details
SPH 3000-6000TL BL-UP
3 – 6 kWSingle-phaseIP65
View details
SUN-3-12K-SG05LP3-EU-SM2
3 – 12 kWThree-phaseIP65
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.