S6-EO1P(4-6)K-48 Off-grid inverter

S6-EO1P(4-6)K-48

Off-grid inverter · Single-phase · 4 – 6 kW

4 – 6 kWSingle-phaseIP21
Price on request
4 – 6 kWRated power
Single-phasePhase
1MPPT trackers
96.6 %Max. efficiency

Technical data

S6-EO1P4K-48S6-EO1P5K-48S6-EO1P6K-48
PV input
Max. usable PV input power (W)550065006500
Max. PV input voltage (V)500
Rated PV input voltage (V)360
Start-up voltage (V)90
MPPT voltage range (V)90 – 430
Max. input current per MPPT (A)16
Max. short-circuit current per MPPT (A)40
Max. PV charge current (A)100100120
Number of MPPT trackers1
PV strings per MPPT2
AC output
Rated output power (W)400050006000
Max. apparent power (VA)400050006000
Rated AC voltage (V)230
Rated grid voltage tolerance (%)+/-1
PhaseSingle-phase
Rated AC frequency (Hz)50/60
Rated grid frequency tolerance (%)+/-0.1
Max. AC output current (A)202530
Surge capability (kVA)81012
Output waveformPure sine wave
Grid / off-grid switching time10 ms (max. 20 ms)
Total voltage harmonic distortion (THDv) (%)<3
Generator inputYes
Max. AC input power (grid port and generator port) (W)600070007000
AC input rated voltage (V)230
AC input voltage range (V)90 – 280
AC input frequency range (Hz)50/60
Max. AC input current (A)263030
Max. AC charge current (A)608080
Max. parallel units6
Battery
Battery typeLithium battery / Lead-acid battery
Battery voltage range (V)40 – 60
Max. charge power (W)500050006000
Max. discharge power (W)500050006000
Max. charge current (A)100100120
Max. discharge current (A)100100120
Battery communicationCAN
Efficiency
Max. efficiency (%)96.6
Protection
Protection functionsAC output over-current protection; AC output over-voltage protection; AC short-circuit protection; Surge protection; Temperature protection; DC arc-fault protection (optional)
General data
Dimensions (W x H x D) (mm)340 × 480 × 170
Weight (kg)13.8
TopologyHigh-frequency, non-isolated
Relative humidity (%)5 – 95
Operating temperature range (°C)−10 – 60
Storage temperature (°C)−25 – 60
Ingress protection (IP rating)IP21
Noise level (dB)<55
Max. operating altitude (m)2000
DC portTerminal block
AC portTerminal block
Communication
DisplayLCD
Communication interfacesCAN; BMS; Dry contact; Bluetooth; Wi-Fi (optional)
Certifications
Certifications and standardsIEC 62109; IEC 61000; 55011

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote