S6-EO1P(4-5)K-48-EU
4 – 5 kWSingle-phaseIP21
View details
S6-EO1P(4-6)K-48
Off-grid inverter · Single-phase · 4 – 6 kW
4 – 6 kWSingle-phaseIP21
Price on request
4 – 6 kWRated power
Single-phasePhase
1MPPT trackers
96.6 %Max. efficiency
Technical data
| S6-EO1P4K-48 | S6-EO1P5K-48 | S6-EO1P6K-48 | |
|---|---|---|---|
| PV input | |||
| Max. usable PV input power (W) | 5500 | 6500 | 6500 |
| Max. PV input voltage (V) | 500 | ||
| Rated PV input voltage (V) | 360 | ||
| Start-up voltage (V) | 90 | ||
| MPPT voltage range (V) | 90 – 430 | ||
| Max. input current per MPPT (A) | 16 | ||
| Max. short-circuit current per MPPT (A) | 40 | ||
| Max. PV charge current (A) | 100 | 100 | 120 |
| Number of MPPT trackers | 1 | ||
| PV strings per MPPT | 2 | ||
| AC output | |||
| Rated output power (W) | 4000 | 5000 | 6000 |
| Max. apparent power (VA) | 4000 | 5000 | 6000 |
| Rated AC voltage (V) | 230 | ||
| Rated grid voltage tolerance (%) | +/-1 | ||
| Phase | Single-phase | ||
| Rated AC frequency (Hz) | 50/60 | ||
| Rated grid frequency tolerance (%) | +/-0.1 | ||
| Max. AC output current (A) | 20 | 25 | 30 |
| Surge capability (kVA) | 8 | 10 | 12 |
| Output waveform | Pure sine wave | ||
| Grid / off-grid switching time | 10 ms (max. 20 ms) | ||
| Total voltage harmonic distortion (THDv) (%) | <3 | ||
| Generator input | Yes | ||
| Max. AC input power (grid port and generator port) (W) | 6000 | 7000 | 7000 |
| AC input rated voltage (V) | 230 | ||
| AC input voltage range (V) | 90 – 280 | ||
| AC input frequency range (Hz) | 50/60 | ||
| Max. AC input current (A) | 26 | 30 | 30 |
| Max. AC charge current (A) | 60 | 80 | 80 |
| Max. parallel units | 6 | ||
| Battery | |||
| Battery type | Lithium battery / Lead-acid battery | ||
| Battery voltage range (V) | 40 – 60 | ||
| Max. charge power (W) | 5000 | 5000 | 6000 |
| Max. discharge power (W) | 5000 | 5000 | 6000 |
| Max. charge current (A) | 100 | 100 | 120 |
| Max. discharge current (A) | 100 | 100 | 120 |
| Battery communication | CAN | ||
| Efficiency | |||
| Max. efficiency (%) | 96.6 | ||
| Protection | |||
| Protection functions | AC output over-current protection; AC output over-voltage protection; AC short-circuit protection; Surge protection; Temperature protection; DC arc-fault protection (optional) | ||
| General data | |||
| Dimensions (W x H x D) (mm) | 340 × 480 × 170 | ||
| Weight (kg) | 13.8 | ||
| Topology | High-frequency, non-isolated | ||
| Relative humidity (%) | 5 – 95 | ||
| Operating temperature range (°C) | −10 – 60 | ||
| Storage temperature (°C) | −25 – 60 | ||
| Ingress protection (IP rating) | IP21 | ||
| Noise level (dB) | <55 | ||
| Max. operating altitude (m) | 2000 | ||
| DC port | Terminal block | ||
| AC port | Terminal block | ||
| Communication | |||
| Display | LCD | ||
| Communication interfaces | CAN; BMS; Dry contact; Bluetooth; Wi-Fi (optional) | ||
| Certifications | |||
| Certifications and standards | IEC 62109; IEC 61000; 55011 | ||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
S6-EO1P(4-5)K-48-EU
4 – 5 kWSingle-phaseIP21
View details
SPF 4-12KT HVM-MPV
4 – 12 kWSingle-phaseIP20
View details
SPF 4000-18000T DVM
4 – 18 kWSplit-phaseIP20
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.