SPE 15KTL3 HVM
15 kWThree-phaseIP20
View details
SUN-15-25K-SG02HP3-EU-DM3
Hybrid inverter · Three-phase · 15 – 25 kW
15 – 25 kWThree-phaseIP65
Price on request
15 – 25 kWRated power
Three-phasePhase
3MPPT trackers
97.6 %Max. efficiency
Technical data
| SUN-15K-SG02HP3-EU-DM3 | SUN-20K-SG02HP3-EU-DM3 | SUN-25K-SG02HP3-EU-DM3 | |
|---|---|---|---|
| PV input | |||
| Max. PV input power (W) | 30000 | 40000 | 50000 |
| Max. usable PV input power (W) | 24000 | 32000 | 40000 |
| Max. PV input voltage (V) | 1000 | ||
| Rated PV input voltage (V) | 600 | ||
| MPPT voltage range (V) | 150 – 850 | ||
| Start-up voltage (V) | 180 | ||
| Max. input current per MPPT (A) | 36 | ||
| Max. short-circuit current per MPPT (A) | 54 | ||
| Number of MPPT trackers | 3 | ||
| PV strings per MPPT | 2 | ||
| Max. operating PV input current per MPPT (A / B / C) (A) | 36 / 20 / 20 | ||
| Max. input short-circuit current per MPPT (A / B / C) (A) | 54 / 30 / 30 | ||
| PV strings per MPPT (A / B / C) | 2 / 1 / 1 | ||
| AC output | |||
| Rated output power (W) | 15000 | 20000 | 25000 |
| Max. apparent power (VA) | 16500 | 22000 | 27500 |
| Rated AC voltage (V) | 400 | ||
| Rated AC output current (A) | 21.8 | 29 | 36.3 |
| Phase | Three-phase | ||
| Rated AC frequency (Hz) | 50/60 | ||
| Max. AC output current (A) | 24 | 31.9 | 39.9 |
| Total harmonic distortion (THDi) (%) | <3 | ||
| Power factor | 0.8 leading to 0.8 lagging | ||
| Peak (surge) power (W) | 22500 | 30000 | 37500 |
| Peak power duration (off-grid) (s) | 10 | ||
| Rated AC voltage options (V) | 220/380; 230/400 | ||
| AC voltage range | 0.85 Un-1.1 Un | ||
| Grid connection type | 3L+N+PE | ||
| Grid frequency range (50 Hz / 60 Hz) (Hz) | 45-55 / 55-65 | ||
| Max. continuous AC passthrough (grid to load) (A) | 60 | ||
| DC injection current | <0.5% In | ||
| Generator input | Yes | ||
| Max. parallel units | 10 | ||
| Unbalanced output capability (%) | 100 | ||
| Battery | |||
| Battery type | Lithium-ion | ||
| Battery voltage range (V) | 160 – 700 | ||
| Max. charge current (A) | 55 | ||
| Max. discharge current (A) | 55 | ||
| Charging strategy for Li-ion battery | Self-adaption to BMS | ||
| Number of battery inputs | 1 | ||
| Efficiency | |||
| Max. efficiency (%) | 97.6 | ||
| European efficiency (%) | 97 | ||
| MPPT efficiency (%) | >99 | ||
| Protection | |||
| Protection functions | DC reverse polarity protection; AC output overcurrent protection; Thermal protection; AC output overvoltage protection; AC output short-circuit protection; DC component monitoring; Arc fault circuit interrupter (AFCI) (optional); Anti-islanding protection; DC switch; Insulation impedance detection; Residual current detection | ||
| Surge protection level | Type II (DC), Type II (AC) | ||
| General data | |||
| Ingress protection (IP rating) | IP65 | ||
| Operating temperature range (°C) | −40 – 60 | ||
| Power derating above (°C) | 45 | ||
| Relative humidity (%) | 0 – 100 | ||
| Max. operating altitude (m) | 3000 | ||
| Cooling | Intelligent air cooling | ||
| Noise level (dB) | ≤45 | ||
| Topology | Non-isolated | ||
| Warranty (years) | 5 – 10 | ||
| Overvoltage category | OVC II (DC), OVC III (AC) | ||
| Communication | |||
| Display | LCD + LED | ||
| Communication interfaces | Wi-Fi; RS485; CAN | ||
| Monitoring | GPRS / Wi-Fi / Bluetooth / 4G | ||
| Certifications | |||
| Certifications and standards | IEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2 | ||
| Grid codes | IEC 61727; IEC 62116; CEI 0-21; EN 50549; NRS 097; RD 140; UNE 217002; OVE-Richtlinie R25; G99; VDE-AR-N 4105 | ||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
SPE 15KTL3 HVM
15 kWThree-phaseIP20
View details
SUN-25-30K-SG02HP3-EU-AM3
25 – 30 kWThree-phaseIP65
View details
WIT 28-55K-HU-AU-US L2
28 – 55 kWThree-phaseIP66
View details
Request a quotation