SUN-M60-100G4-EU-Q0
0.6 – 1 kWSingle-phaseIP67
View details
SUN-M60-100G4-EU-Q0-P
Microinverter · Single-phase · 0.6 – 1 kW
0.6 – 1 kWSingle-phaseIP67
Price on request
0.6 – 1 kWRated power
Single-phasePhase
2MPPT trackers
96.5 %Max. efficiency
Technical data
| SUN-M60G4-EU-Q0-P | SUN-M80G4-EU-Q0-P | SUN-M100G4-EU-Q0-P | |
|---|---|---|---|
| PV input | |||
| Recommended PV module power (W) | 210 – 420 | 210 – 560 | 210 – 700 |
| Number of connectable PV modules | 2 | ||
| Max. PV input voltage (V) | 60 | ||
| Rated PV input voltage (V) | 42.5 | ||
| MPPT voltage range (V) | 25 – 55 | ||
| Start-up voltage (V) | 20 | ||
| Max. input current per MPPT (A) | 18 | ||
| Max. short-circuit current per MPPT (A) | 27 | ||
| Number of MPPT trackers | 2 | ||
| PV strings per MPPT | 1 | ||
| AC output | |||
| Rated output power (W) | 600 | 800 | 1000 |
| Max. apparent power (VA) | 600 | 800 | 1000 |
| Rated AC voltage (V) | 230 | ||
| Rated AC output current (A) | 2.7 | 3.5 | 4.4 |
| Max. AC output current (A) | 2.7 | 3.5 | 4.4 |
| Phase | Single-phase | ||
| Rated AC frequency (Hz) | 50/60 | ||
| Power factor | 0.9 leading to 0.9 lagging (adjustable) | ||
| Total harmonic distortion (THDi) (%) | <3 | ||
| Max. units per AC branch | 8 | 6 | 5 |
| AC voltage range | 0.85 Un-1.1 Un | ||
| Grid connection | L/N/PE | ||
| AC grid frequency range | 50 Hz: 45-55 Hz; 60 Hz: 55-65 Hz | ||
| DC injection current | <0.5% In | ||
| Efficiency | |||
| Max. efficiency (%) | 96.5 | ||
| European efficiency (%) | 96 | ||
| MPPT efficiency (%) | >99 | ||
| Protection | |||
| Protection functions | DC reverse polarity protection; AC output overcurrent protection; AC output overvoltage protection; AC output short-circuit protection; Thermal protection; Insulation impedance detection; Anti-islanding protection; AC surge protection (Type II) | ||
| Other safety features | Rapid shutdown function; AC fast discharge <100 ms (meets DIN VDE V 0126-95, <200 ms); NS protection with self-check function | ||
| General data | |||
| Dimensions (W x H x D) (mm) | 280.5 × 190 × 40 | ||
| Weight (kg) | 3 | ||
| Ingress protection (IP rating) | IP67 | ||
| Operating temperature range (°C) | −40 – 65 | ||
| Power derating above (°C) | 45 | ||
| Relative humidity (%) | 0 – 100 | ||
| Max. operating altitude (m) | 2000 | ||
| Cooling | Natural cooling | ||
| Noise level (dB) | ≤25 | ||
| Topology | Isolated | ||
| Overvoltage category | OVC II (DC); OVC III (AC) | ||
| Warranty (years) | 15 | ||
| Design lifetime (years) | 25 | ||
| Communication | |||
| Communication interfaces | Wi-Fi | ||
| Monitoring | Module-level monitoring | ||
| Certifications | |||
| Certifications and standards | IEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2 | ||
| Grid codes | IEC 61727; IEC 62116; CEI 0-21; EN 50549; NRS 097; RD 140; UNE 217002; G98; VDE-AR-N 4105 | ||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads