G6-GR3P(5-10)K02-NV-ND
5 – 10 kWThree-phaseIP66
View details
GCI-3P(5-25)K-5G-PLUS
String inverter · Three-phase · 5 – 25 kW
5 – 25 kWThree-phaseIP66
Price on request
5 – 25 kWRated power
Three-phasePhase
2MPPT trackers
98.3 – 98.5 %Max. efficiency
Technical data
| GCI-3P5K-5G-PLUS | GCI-3P6K-5G-PLUS | GCI-3P8K-5G-PLUS | GCI-3P10K-5G-PLUS | GCI-3P12K-5G-PLUS | GCI-3P13K-5G-PLUS | GCI-3P15K-5G-PLUS | GCI-3P17K-5G-PLUS | GCI-3P20K-5G-PLUS | GCI-3P23K-5G-PLUS | GCI-3P25K-5G-PLUS | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| PV input | |||||||||||
| Max. PV input power (W) | 6000 | 7200 | 9600 | 12000 | 14500 | 15000 | 18000 | 20400 | 24000 | 28000 | 30000 |
| Max. PV input voltage (V) | 1100 | ||||||||||
| Rated PV input voltage (V) | 600 | ||||||||||
| Start-up voltage (V) | 180 | ||||||||||
| MPPT voltage range (V) | 160 – 1000 | ||||||||||
| Max. input current per MPPT (A) | 20 | 20 | 20 | 20 | 20 | 32 | 32 | 32 | 32 | 40 | 40 |
| Max. short-circuit current per MPPT (A) | 25 | 25 | 25 | 25 | 25 | 50 | 50 | 50 | 50 | 50 | 50 |
| Number of MPPT trackers | 2 | ||||||||||
| PV strings per MPPT | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 |
| Max. PV input current by MPPT tracker (A) | 20 / 18 | 20 / 18 | 20 / 18 | 20 / 18 | 20 / 18 | 32 / 20 | 32 / 20 | 32 / 32 | 32 / 32 | 40 / 32 | 40 / 32 |
| Max. PV short-circuit current by MPPT tracker (A) | 25 / 25 | 25 / 25 | 25 / 25 | 25 / 25 | 25 / 25 | 50 / 25 | 50 / 25 | 50 / 50 | 50 / 50 | 50 / 50 | 50 / 50 |
| Max. number of input strings | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 4 | 4 | 4 | 4 |
| AC output | |||||||||||
| Rated output power (W) | 5000 | 6000 | 8000 | 10000 | 12000 | 13000 | 15000 | 17000 | 20000 | 23000 | 25000 |
| Max. apparent power (VA) | 5500 | 6600 | 8800 | 11000 | 13200 | 14300 | 16500 | 18700 | 22000 | 25300 | 27500 |
| Max. active power (W) | 5500 | 6600 | 8800 | 11000 | 13200 | 14300 | 16500 | 18700 | 22000 | 25300 | 27500 |
| Rated AC voltage (V) | 380 | ||||||||||
| Grid connection type | 3/N/PE | ||||||||||
| Phase | Three-phase | ||||||||||
| Rated AC frequency (Hz) | 50 | ||||||||||
| Rated AC output current (A) | 7.6 | 9.1 | 12.2 | 15.2 | 18.2 | 19.8 | 22.8 | 25.8 | 30.4 | 34.9 | 38 |
| Max. AC output current (A) | 8.4 | 10 | 13.4 | 16.7 | 20.1 | 21.7 | 25.1 | 28.4 | 33.5 | 38.4 | 41.8 |
| Power factor | >0.99 (0.8 leading to 0.8 lagging) | ||||||||||
| Total harmonic distortion (THDi) (%) | <3 | ||||||||||
| Efficiency | |||||||||||
| Max. efficiency (%) | 98.3 | 98.3 | 98.4 | 98.4 | 98.4 | 98.4 | 98.4 | 98.5 | 98.5 | 98.5 | 98.5 |
| China efficiency (%) | 97.7 | 97.7 | 97.9 | 97.9 | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 | 98.1 | 98.1 |
| Protection | |||||||||||
| Protection functions | DC reverse polarity protection; AC short-circuit protection; AC output overcurrent protection; Surge protection; Grid monitoring; Anti-islanding protection; Temperature protection; I-V curve scanning; Multi-peak scanning; Integrated DC switch; DC arc-fault protection (AFCI) (optional) | ||||||||||
| General data | |||||||||||
| Dimensions (W x H x D) (mm) | 310 × 550 × 219 | ||||||||||
| Weight (kg) | 16.5 | 16.5 | 17.1 | 17.1 | 17.1 | 18.4 | 18.4 | 20.4 | 20.4 | 20.4 | 20.4 |
| Topology | Transformerless | ||||||||||
| Night-time power consumption (W) | <1 | ||||||||||
| Operating temperature range (°C) | −25 – 60 | ||||||||||
| Relative humidity (%) | 0 – 100 | ||||||||||
| Ingress protection (IP rating) | IP66 | ||||||||||
| Noise level (dB) | <30 | <30 | <30 | <30 | <30 | <30 | <30 | <60 | <60 | <60 | <60 |
| Cooling | Natural cooling | Natural cooling | Natural cooling | Natural cooling | Natural cooling | Natural cooling | Natural cooling | Intelligent air cooling | Intelligent air cooling | Intelligent air cooling | Intelligent air cooling |
| Max. operating altitude (m) | 4000 | ||||||||||
| DC connection | MC4 connector | ||||||||||
| AC connection | OT terminal | ||||||||||
| AC wiring compatibility | 25 mm² aluminium cable | ||||||||||
| Communication | |||||||||||
| Display | LED indicators | ||||||||||
| Communication interfaces | RS485 (2 independent ports); GPRS; 4G | ||||||||||
| Monitoring | Bluetooth + app; 24-hour load consumption monitoring | ||||||||||
| Certifications | |||||||||||
| Certifications and standards | IEC 62109-1/-2; IEC 61000-6-1/-2/-3/-4; NB/T 32004 | ||||||||||
| Grid codes | NB/T 32004 | ||||||||||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
G6-GR3P(5-10)K02-NV-ND
5 – 10 kWThree-phaseIP66
View details
SUN-6-8K-G06P3-EU-BM2-LV-P1
6 – 8 kWThree-phaseIP65
View details
G6-GR1P(7-8)K2
7 – 8 kWSingle-phaseIP66
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.