G6-GR1P(1-3.6)K-M
1 – 3.6 kWSingle-phaseIP66
View details
MIC 750-3300TL-X-X2(Pro)
String inverter · Single-phase · 0.75 – 3.3 kW
0.75 – 3.3 kWSingle-phaseIP65
Price on request
0.75 – 3.3 kWRated power
Single-phasePhase
1MPPT trackers
97.4 – 97.6 %Max. efficiency
Technical data
| MIC 750TL-X | MIC 1000TL-X | MIC 1500TL-X | MIC 2000TL-X | MIC 2500TL-X | MIC 3000TL-X | MIC 3300TL-X | MIC 750TL-X2 | MIC 800TL-X2 | MIC 1000TL-X2 | MIC 1500TL-X2 | MIC 2000TL-X2 | MIC 2500TL-X2 | MIC 3000TL-X2 | MIC 3300TL-X2 | MIC 1000TL-X2 (Pro) | MIC 2000TL-X2 (Pro) | MIC 3000TL-X2 (Pro) | MIC 3300TL-X2 (Pro) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PV input | |||||||||||||||||||
| Max. PV input power (W) | 1050 | 1400 | 2100 | 2800 | 3500 | 4200 | 4290 | 1120 | 1200 | 1500 | 2250 | 3000 | 3750 | 4500 | 4950 | 1500 | 3000 | 4500 | 4950 |
| Max. PV input voltage (V) | 500 | 500 | 500 | 500 | 550 | 550 | 550 | 500 | 500 | 500 | 500 | 500 | 550 | 550 | 550 | 500 | 500 | 550 | 550 |
| Start-up voltage (V) | 50 | 50 | 50 | 50 | 80 | 80 | 80 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Rated PV input voltage (V) | 120 | 180 | 250 | 360 | 360 | 360 | 360 | 120 | 120 | 180 | 250 | 360 | 360 | 360 | 360 | 180 | 360 | 360 | 360 |
| MPPT voltage range (V) | 50 – 500 | 50 – 500 | 50 – 500 | 50 – 500 | 65 – 550 | 65 – 550 | 65 – 550 | 50 – 500 | 50 – 500 | 50 – 500 | 50 – 500 | 50 – 500 | 50 – 550 | 50 – 550 | 50 – 550 | 50 – 500 | 50 – 500 | 50 – 550 | 50 – 550 |
| Number of MPPT trackers | 1 | ||||||||||||||||||
| PV strings per MPPT | 1 | ||||||||||||||||||
| Max. input current per MPPT (A) | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 18 | 18 | 18 | 18 |
| Max. short-circuit current per MPPT (A) | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
| AC output | |||||||||||||||||||
| Rated output power (W) | 750 | 1000 | 1500 | 2000 | 2500 | 3000 | 3300 | 750 | 800 | 1000 | 1500 | 2000 | 2500 | 3000 | 3300 | 1000 | 2000 | 3000 | 3300 |
| Max. apparent power (VA) | 750 | 1000 | 1500 | 2000 | 2500 | 3000 | 3300 | 750 | 800 | 1000 | 1500 | 2000 | 2500 | 3000 | 3300 | 1000 | 2000 | 3000 | 3300 |
| Rated AC voltage (V) | 230 | ||||||||||||||||||
| AC voltage range (V) | 180 – 280 | ||||||||||||||||||
| Phase | Single-phase | ||||||||||||||||||
| Rated AC frequency (Hz) | 50/60 | ||||||||||||||||||
| Grid frequency range (50 Hz / 60 Hz) (Hz) | 45-55 / 55-65 | ||||||||||||||||||
| Max. AC output current (A) | 3.6 | 4.8 | 7.1 | 9.5 | 11.9 | 14.3 | 14.3 | 3.6 | 3.8 | 4.8 | 7.1 | 9.5 | 11.9 | 14.3 | 14.3 | 4.8 | 9.5 | 14.3 | 14.3 |
| Total harmonic distortion (THDi) (%) | <3 | ||||||||||||||||||
| Power factor | 0.8 leading to 0.8 lagging (adjustable) | ||||||||||||||||||
| Efficiency | |||||||||||||||||||
| Max. efficiency (%) | 97.4 | 97.4 | 97.4 | 97.4 | 97.6 | 97.6 | 97.6 | 97.4 | 97.4 | 97.4 | 97.4 | 97.4 | 97.6 | 97.6 | 97.6 | 97.4 | 97.4 | 97.6 | 97.6 |
| European efficiency (%) | 96.5 | 96.5 | 97 | 97 | 97 | 97.1 | 97.1 | 96.5 | 96.5 | 96.5 | 97 | 97 | 97 | 97.1 | 97.1 | 96.5 | 97 | 97.1 | 97.1 |
| MPPT efficiency (%) | 99.9 | ||||||||||||||||||
| Protection | |||||||||||||||||||
| Protection functions | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; AC/DC surge protection (Type III / Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) |
| General data | |||||||||||||||||||
| Dimensions (W x H x D) (mm) | 274 × 254 × 138 | ||||||||||||||||||
| Weight (kg) | 6 | 6 | 6 | 6 | 6.2 | 6.2 | 6.2 | 6 | 6 | 6 | 6 | 6.2 | 6.2 | 6.2 | 6.2 | 6 | 6.2 | 6.2 | 6.2 |
| Operating temperature range (°C) | −25 – 60 | −25 – 60 | −25 – 60 | −25 – 60 | −25 – 60 | −25 – 60 | −25 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 |
| Night-time power consumption (W) | <0.5 | ||||||||||||||||||
| Topology | Transformerless | ||||||||||||||||||
| Cooling | Natural convection | ||||||||||||||||||
| Ingress protection (IP rating) | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Relative humidity (%) | 0 – 100 | 0 – 100 | 0 – 100 | 0 – 100 | 0 – 100 | 0 – 100 | 0 – 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
| Max. operating altitude (m) | 4000 | ||||||||||||||||||
| DC connector | H4; MC4 (optional) | ||||||||||||||||||
| AC connector | Connector | ||||||||||||||||||
| Warranty (years) | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 8 – 10 | 8 – 10 | 8 – 10 | 8 – 10 |
| Communication | |||||||||||||||||||
| Display | OLED + LED | ||||||||||||||||||
| Communication interfaces | RS485; USB; Wi-Fi (optional); GPRS (optional); RF (optional); LAN (optional) | ||||||||||||||||||
| Monitoring | Wi-Fi + app | ||||||||||||||||||
| Certifications | |||||||||||||||||||
| Certifications and standards | CE; UKCA; INMETRO; IEC 62109-1; IEC 62109-2 | CE; UKCA; INMETRO; IEC 62109-1; IEC 62109-2 | CE; UKCA; INMETRO; IEC 62109-1; IEC 62109-2 | CE; UKCA; INMETRO; IEC 62109-1; IEC 62109-2 | CE; UKCA; INMETRO; IEC 62109-1; IEC 62109-2 | CE; UKCA; INMETRO; IEC 62109-1; IEC 62109-2 | CE; UKCA; INMETRO; IEC 62109-1; IEC 62109-2 | CE; UKCA; INMETRO; BIS; KS | CE; UKCA; INMETRO; BIS; KS | CE; UKCA; INMETRO; BIS; KS | CE; UKCA; INMETRO; BIS; KS | CE; UKCA; INMETRO; BIS; KS | CE; UKCA; INMETRO; BIS; KS | CE; UKCA; INMETRO; BIS; KS | CE; UKCA; INMETRO; BIS; KS | CE; BIS | CE; BIS | CE; BIS | CE; BIS |
| Grid codes | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; UNE 217001; UNE 217002; Poland; AS/NZS 4777.2 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; UNE 217001; UNE 217002; Poland; AS/NZS 4777.2 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; UNE 217001; UNE 217002; Poland; AS/NZS 4777.2 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; UNE 217001; UNE 217002; Poland; AS/NZS 4777.2 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; UNE 217001; UNE 217002; Poland; AS/NZS 4777.2 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; UNE 217001; UNE 217002; Poland; AS/NZS 4777.2 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; UNE 217001; UNE 217002; Poland; AS/NZS 4777.2 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; EN 50549-10; G99 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; EN 50549-10; G99 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; EN 50549-10; G99 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; EN 50549-10; G99 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; EN 50549-10; G99 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; EN 50549-10; G99 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; EN 50549-10; G99 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 60068; IEC 61683; IEC 62116; IEC 61727; G98; C10/C11; EN 50549-10; G99 | – | – | – | – |
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
G6-GR1P(1-3.6)K-M
1 – 3.6 kWSingle-phaseIP66
View details
SUN-1-4K-G04P1-EU-AM1
1 – 4 kWSingle-phaseIP65
View details
SUN-1-4K-G04P1-EU-CM1
1 – 4 kWSingle-phaseIP65
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.