MID 29.9-50K-HU Hybrid inverter

MID 29.9-50K-HU

Hybrid inverter · Three-phase · 29.9 – 50 kW

29.9 – 50 kWThree-phaseIP66
Price on request
29.9 – 50 kWRated power
Three-phasePhase
3 – 4MPPT trackers
98.6 %Max. efficiency

Technical data

MID 29.9K-HUMID 30K-HUMID 33K-HUMID 36K-HUMID 40K-HUMID 50K-HU
PV input
Max. PV input power (W)5980060000660007200080000100000
Max. PV input voltage (V)1000
Rated PV input voltage (V)600
MPPT voltage range (V)200 – 1000
Full-power MPPT voltage range (V)400 – 800400 – 800400 – 800400 – 800450 – 800450 – 800
Start-up voltage (V)160
Max. input current per MPPT (A)40
Max. short-circuit current per MPPT (A)50
Number of MPPT trackers333344
PV strings per MPPT2
AC output
Rated output power (W)299003000033000360004000050000
Max. apparent power (VA)299003300036300396004400050000
Rated AC voltage (V)400
Rated AC voltage options (V)220/380; 230/400
PhaseThree-phase
Grid connection type3W+N+PE / 3W+PE
Rated AC frequency (Hz)50/60
Grid frequency range (50 Hz / 60 Hz) (Hz)45-55 / 55-65
Max. AC output current (A)45.350556066.775.8
Power factor> 0.99 at nominal power; adjustable 0.8 leading to 0.8 lagging
Total harmonic distortion (THDi) (%)<3
Three-phase unbalanced outputSupported only with APX HV Battery 1.0 / 2.0
AC nominal input power (grid side) (W)359003600039600432004800060000
Max. AC input apparent power (grid side) (VA)359003600039600432004800060000
Max. AC input current (grid side) (A)54.454.56065.572.790.9
Backup output power (W)299003000033000360004000050000
Max. backup apparent power (VA)299003000033000360004000050000
Nominal backup AC voltage (V)220/380; 230/400
Nominal backup AC frequency (Hz)50 / 60
Max. backup output current (A)45.345.55054.560.675.8
Peak (surge) power (W)358803600039600432004800060000
Backup overload duration (s)10
Backup THDv (%)<3
Backup switch time (ms)<150
Battery
Compatible batteryAPX HV Battery 1.0; APX HV Battery 2.0 (5 kWh-30 kWh)
Battery voltage range (V)600 – 980
Battery operating voltage range by battery model (V)APX HV Battery 1.0: 600-980; APX HV Battery 2.0: 660-980
Max. battery operating current (APX HV Battery 1.0 / 2.0) (A)83.3 / 75.8
Max. discharge power with APX HV Battery 1.0 (W)299003000030000300003000030000
Max. discharge power with APX HV Battery 2.0 (W)299003000033000360004000045000
Max. charge power (W)50000
Efficiency
Max. efficiency (%)98.6
European efficiency (%)97.2
Protection
Protection functionsDC switch; DC reverse polarity protection; AC/DC surge protection (Type II); Insulation resistance monitoring; Output surge protection (Type II); AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)
General data
Dimensions (W x H x D) (mm)680 × 570 × 256
Weight (kg)484848485050
Operating temperature range (°C)−25 – 60
Power derating above (°C)45
Noise level (dB)≤55
Max. operating altitude (m)4000
Night-time power consumption (W)<25
TopologyTransformerless
CoolingSmart air cooling
Ingress protection (IP rating)IP66
Relative humidity (%)0 – 100
DC connectionH4 / MC4 (optional)
AC connectionWaterproof PG connector + OT terminal
Warranty (years)5 – 10
Communication
DisplayOLED + LED / Wi-Fi + App
Communication interfacesRS485; CAN; USB
MonitoringOptional external monitoring modules (Wi-Fi/LAN, 4G, data logger)
Certifications
Certifications and standardsCE
Grid codesN4105; EN 50549-1; C10/C11; CEI 0-21; G99; G100

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote