MOD 3-15KTL3-X-X2(Pro) String inverter

MOD 3-15KTL3-X-X2(Pro)

String inverter · Three-phase · 3 – 15 kW

3 – 15 kWThree-phaseIP66
Price on request
3 – 15 kWRated power
Three-phasePhase
2MPPT trackers
98.3 – 98.6 %Max. efficiency

Technical data

MOD 3000TL3-XMOD 4000TL3-XMOD 5000TL3-XMOD 6000TL3-XMOD 7000TL3-XMOD 8000TL3-XMOD 9000TL3-XMOD 10KTL3-XMOD 11KTL3-XMOD 12KTL3-XMOD 13KTL3-XMOD 15KTL3-XMOD 3000TL3-X2 (Pro)MOD 4000TL3-X2 (Pro)MOD 5000TL3-X2 (Pro)MOD 6000TL3-X2 (Pro)
PV input
Max. PV input power (W)450060007500900010500120001350015000165001800019500225004500600075009000
Max. PV input voltage (V)1100
Start-up voltage (V)160
Rated PV input voltage (V)580580580580580580580580580580580580600600600600
MPPT voltage range (V)140 – 1000
Number of MPPT trackers2
PV strings per MPPT1111111112221111
Max. input current per MPPT (A)13131313131313131326262620202020
Max. short-circuit current per MPPT (A)16161616161616161632323225252525
AC output
Rated output power (W)300040005000600070008000900010000110001200013000150003000400050006000
Max. apparent power (VA)330044005500660077008800990011000121001320014300165003300440055006600
Rated AC voltage (V)400
Nominal AC voltage options (V)220/380 or 230/400
AC voltage range (V)340 – 440
PhaseThree-phase
Rated AC frequency (Hz)50/60
AC grid frequency range (50 Hz / 60 Hz) (Hz)45-55 / 55-65
Max. AC output current (A)56.78.31011.713.31516.718.32021.72556.78.310
Power factor0.8 leading to 0.8 lagging (adjustable)
Total harmonic distortion (THDi) (%)<3
AC grid connection type3W+N+PE
Efficiency
Max. efficiency (%)98.398.398.398.398.698.698.698.698.698.698.698.698.398.398.398.3
European efficiency (%)97.597.597.597.598.198.198.198.198.198.298.298.297.597.597.597.5
MPPT efficiency (%)99.9
Protection
Protection functionsDC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; DC switch; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)DC reverse polarity protection; Surge protection (AC Type II / DC Type II); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; String fault monitoring; AFCI protection (optional)
General data
Dimensions (W x H x D) (mm)425 × 387 × 147425 × 387 × 147425 × 387 × 147425 × 387 × 147425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178425 × 387 × 178
Weight (kg)12.512.512.512.5141414141416161614.614.614.614.6
Ingress protection (IP rating)IP66
Operating temperature range (°C)−25 – 60
Relative humidity (%)0 – 100
Max. operating altitude (m)4000
CoolingNatural convection
TopologyTransformerless
Night-time power consumption (W)<1
Warranty (years)5 – 10
DC connectionH4 / MC4 (optional)
AC connectionConnector
Communication
DisplayOLED + LED; Wi-Fi + app
Communication interfacesUSB; RS485; Wi-Fi (optional); GPRS (optional); LAN (optional); RF (optional)
Certifications
Certifications and standardsCE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; IEC 60068; IEC 61683CE; BIS; DRRG; IEC 60068; IEC 61683; IEC 62910; IEC 63027CE; BIS; DRRG; IEC 60068; IEC 61683; IEC 62910; IEC 63027CE; BIS; DRRG; IEC 60068; IEC 61683; IEC 62910; IEC 63027CE; BIS; DRRG; IEC 60068; IEC 61683; IEC 62910; IEC 63027
Grid codesVDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2VDE 0126; Greece; EN 50549; C10/C11; UTE C 15-712; IEC 62116; IEC 61727; CEI 0-21; N4105; TOR Erzeuger; G98; G99; G100; AS 4777; UNE 217001; UNE 206007; PO 12.2IEC 62116; IEC 61727; CEI; G98; G99IEC 62116; IEC 61727; CEI; G98; G99IEC 62116; IEC 61727; CEI; G98; G99IEC 62116; IEC 61727; CEI; G98; G99

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

User manuals

  • MOD 3-15KTL3-X-X2(Pro) user manual (English) (4)PDF · 2.1 MBDownload
  • MOD 3-15KTL3-X-X2(Pro) user manual (English) (5)PDF · 2.5 MBDownload
  • MOD 3-15KTL3-X-X2(Pro) user manual (English) (6)PDF · 3.0 MBDownload

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote