G6-GR1P(2.5-6)K-S(21A)
2.5 – 6 kWSingle-phaseIP66
View details
MIN 2500-6000TL-X-X2(Pro)
String inverter · Single-phase · 2.5 – 6 kW
2.5 – 6 kWSingle-phaseIP65
Price on request
2.5 – 6 kWRated power
Single-phasePhase
1 – 2MPPT trackers
98.2 – 98.4 %Max. efficiency
Technical data
| MIN 2500TL-X | MIN 3000TL-X | MIN 3600TL-X | MIN 4200TL-X | MIN 4600TL-X | MIN 5000TL-X | MIN 6000TL-X | MIN 2500TL-X2 | MIN 3000TL-X2 | MIN 3600TL-X2 | MIN 4200TL-X2 | MIN 4600TL-X2 | MIN 5000TL-X2 | MIN 6000TL-X2 | MIN 4200TL-X2 (Pro) | MIN 4600TL-X2 (Pro) | MIN 5000TL-X2 (Pro) | MIN 6000TL-X2 (Pro) | MIN 4200TL-X2 (Pro E) | MIN 5000TL-X2 (Pro E) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PV input | ||||||||||||||||||||
| Max. PV input power (W) | 3500 | 4200 | 5040 | 5880 | 6440 | 7000 | 8100 | 3750 | 4500 | 5400 | 6300 | 6900 | 7500 | 9000 | 6300 | 6900 | 7500 | 9000 | 6300 | 7500 |
| Max. PV input voltage (V) | 500 | 500 | 550 | 550 | 550 | 550 | 550 | 500 | 500 | 550 | 550 | 550 | 550 | 550 | 550 | 550 | 550 | 550 | 550 | 550 |
| Start-up voltage (V) | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Rated PV input voltage (V) | 360 | |||||||||||||||||||
| MPPT voltage range (V) | 80 – 500 | 80 – 500 | 80 – 550 | 80 – 550 | 80 – 550 | 80 – 550 | 80 – 550 | 40 – 500 | 40 – 500 | 40 – 550 | 40 – 550 | 40 – 550 | 40 – 550 | 40 – 550 | 40 – 550 | 40 – 550 | 40 – 550 | 40 – 550 | 40 – 550 | 40 – 550 |
| Number of MPPT trackers | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 1 | 1 |
| PV strings per MPPT | 1 | |||||||||||||||||||
| Max. input current per MPPT (A) | 13.5 | 13.5 | 13.5 | 13.5 | 13.5 | 13.5 | 13.5 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 18 | 18 | 18 | 18 | 18 | 18 |
| Max. short-circuit current per MPPT (A) | 16.9 | 16.9 | 16.9 | 16.9 | 16.9 | 16.9 | 16.9 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
| AC output | ||||||||||||||||||||
| Rated output power (W) | 2500 | 3000 | 3600 | 4200 | 4600 | 5000 | 6000 | 2500 | 3000 | 3600 | 4200 | 4600 | 5000 | 6000 | 4200 | 4600 | 5000 | 6000 | 4200 | 5000 |
| Max. apparent power (VA) | 2500 | 3000 | 3600 | 4200 | 4600 | 5000 | 6000 | 2500 | 3000 | 3600 | 4200 | 4600 | 5000 | 6000 | 4200 | 4600 | 5000 | 6000 | 4200 | 5000 |
| Rated AC voltage (V) | 230 | |||||||||||||||||||
| Phase | Single-phase | |||||||||||||||||||
| Rated AC frequency (Hz) | 50/60 | |||||||||||||||||||
| Max. AC output current (A) | 11.3 | 13.6 | 16 | 19 | 20.9 | 22.7 | 27.2 | 11.3 | 13.6 | 16 | 19 | 20.9 | 22.7 | 27.2 | 19 | 20.9 | 22.7 | 27.2 | 19 | 22.7 |
| Power factor | 0.8 leading to 0.8 lagging (adjustable) | |||||||||||||||||||
| Total harmonic distortion (THDi) (%) | <3 | |||||||||||||||||||
| AC voltage range (V) | 180 – 280 | 180 – 280 | 180 – 280 | 180 – 280 | 180 – 280 | 180 – 280 | 180 – 280 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 | 160 – 300 |
| AC grid frequency range (50 Hz / 60 Hz) (Hz) | 45-55 / 55-65 | 45-55 / 55-65 | 45-55 / 55-65 | 45-55 / 55-65 | 45-55 / 55-65 | 45-55 / 55-65 | 45-55 / 55-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 | 45-55 / 54-65 |
| Efficiency | ||||||||||||||||||||
| Max. efficiency (%) | 98.2 | 98.2 | 98.2 | 98.4 | 98.4 | 98.4 | 98.4 | 98.2 | 98.2 | 98.2 | 98.4 | 98.4 | 98.4 | 98.4 | 98.4 | 98.4 | 98.4 | 98.4 | 98.4 | 98.4 |
| European efficiency (%) | 97.1 | 97.1 | 97.2 | 97.5 | 97.5 | 97.5 | 97.5 | 97.1 | 97.1 | 97.2 | 97.2 | 97.5 | 97.5 | 97.5 | 97.2 | 97.5 | 97.5 | 97.5 | 97.2 | 97.5 |
| MPPT efficiency (%) | 99.9 | |||||||||||||||||||
| Protection | ||||||||||||||||||||
| Protection functions | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch (optional); DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) | DC reverse polarity protection; DC switch (optional); DC surge protection (Type II); AC surge protection (Type III); Insulation resistance monitoring; AC short-circuit protection; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; AFCI protection (optional) |
| General data | ||||||||||||||||||||
| Dimensions (W x H x D) (mm) | 375 × 350 × 160 | 375 × 350 × 160 | 375 × 350 × 160 | 375 × 350 × 160 | 375 × 350 × 160 | 375 × 350 × 160 | 375 × 350 × 160 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 | 375 × 350 × 158 |
| Weight (kg) | 10.8 | |||||||||||||||||||
| Ingress protection (IP rating) | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating temperature range (°C) | −25 – 60 | −25 – 60 | −25 – 60 | −25 – 60 | −25 – 60 | −25 – 60 | −25 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 | −30 – 60 |
| Relative humidity (%) | 0 – 100 | |||||||||||||||||||
| Max. operating altitude (m) | 4000 | |||||||||||||||||||
| Cooling | Natural convection | |||||||||||||||||||
| Noise level (dB) | ≤35 | ≤35 | ≤35 | ≤35 | ≤35 | ≤35 | ≤35 | – | – | – | – | – | – | – | – | – | – | – | – | – |
| Topology | Transformerless | |||||||||||||||||||
| Night-time power consumption (W) | <1 | |||||||||||||||||||
| Warranty (years) | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 5 – 10 | 8 – 10 | 8 – 10 | 8 – 10 | 8 – 10 | 8 – 10 | 8 – 10 |
| DC connection | H4 / MC4 (optional) | |||||||||||||||||||
| AC connection | Connector | |||||||||||||||||||
| Communication | ||||||||||||||||||||
| Display | OLED + LED; Wi-Fi + app | OLED + LED; Wi-Fi + app | OLED + LED; Wi-Fi + app | OLED + LED; Wi-Fi + app | OLED + LED; Wi-Fi + app | OLED + LED; Wi-Fi + app | OLED + LED; Wi-Fi + app | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED | OLED + LED |
| Communication interfaces | RS485; USB; Wi-Fi (optional); GPRS (optional); RF (optional); LAN (optional) | |||||||||||||||||||
| Certifications | ||||||||||||||||||||
| Certifications and standards | CE; UKCA; CQC; INMETRO; IEC 62109; IEC 61683; IEC 60068 | CE; UKCA; CQC; INMETRO; IEC 62109; IEC 61683; IEC 60068 | CE; UKCA; CQC; INMETRO; IEC 62109; IEC 61683; IEC 60068 | CE; UKCA; CQC; INMETRO; IEC 62109; IEC 61683; IEC 60068 | CE; UKCA; CQC; INMETRO; IEC 62109; IEC 61683; IEC 60068 | CE; UKCA; CQC; INMETRO; IEC 62109; IEC 61683; IEC 60068 | CE; UKCA; CQC; INMETRO; IEC 62109; IEC 61683; IEC 60068 | CE; UKCA; UL 1741 | CE; UKCA; UL 1741 | CE; UKCA; UL 1741 | CE; UKCA; UL 1741 | CE; UKCA; UL 1741 | CE; UKCA; UL 1741 | CE; UKCA; UL 1741 | CE; BIS | CE; BIS | CE; BIS | CE; BIS | CE; BIS | CE; BIS |
| Grid codes | VDE 0126-1-1; AS 4777; AS/NZS 4777.2; VDE-AR-N 4105; IEC 62116; IEC 61727; G98; G99; IEEE 1547; PO 12.2; UNE 206007; UNE 217001; NTS Type A | VDE 0126-1-1; AS 4777; AS/NZS 4777.2; VDE-AR-N 4105; IEC 62116; IEC 61727; G98; G99; IEEE 1547; PO 12.2; UNE 206007; UNE 217001; NTS Type A | VDE 0126-1-1; AS 4777; AS/NZS 4777.2; VDE-AR-N 4105; IEC 62116; IEC 61727; G98; G99; IEEE 1547; PO 12.2; UNE 206007; UNE 217001; NTS Type A | VDE 0126-1-1; AS 4777; AS/NZS 4777.2; VDE-AR-N 4105; IEC 62116; IEC 61727; G98; G99; IEEE 1547; PO 12.2; UNE 206007; UNE 217001; NTS Type A | VDE 0126-1-1; AS 4777; AS/NZS 4777.2; VDE-AR-N 4105; IEC 62116; IEC 61727; G98; G99; IEEE 1547; PO 12.2; UNE 206007; UNE 217001; NTS Type A | VDE 0126-1-1; AS 4777; AS/NZS 4777.2; VDE-AR-N 4105; IEC 62116; IEC 61727; G98; G99; IEEE 1547; PO 12.2; UNE 206007; UNE 217001; NTS Type A | VDE 0126-1-1; AS 4777; AS/NZS 4777.2; VDE-AR-N 4105; IEC 62116; IEC 61727; G98; G99; IEEE 1547; PO 12.2; UNE 206007; UNE 217001; NTS Type A | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 62116; IEC 61727; G99; C10/C11; UNE 217001; UNE 206007; PO 12.2; IEEE 1547 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 62116; IEC 61727; G99; C10/C11; UNE 217001; UNE 206007; PO 12.2; IEEE 1547 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 62116; IEC 61727; G99; C10/C11; UNE 217001; UNE 206007; PO 12.2; IEEE 1547 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 62116; IEC 61727; G99; C10/C11; UNE 217001; UNE 206007; PO 12.2; IEEE 1547 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 62116; IEC 61727; G99; C10/C11; UNE 217001; UNE 206007; PO 12.2; IEEE 1547 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 62116; IEC 61727; G99; C10/C11; UNE 217001; UNE 206007; PO 12.2; IEEE 1547 | CEI 0-21; VDE-AR-N 4105; VDE 0126-1-1; VFR 2019; EN 50549-1; IEC 62116; IEC 61727; G99; C10/C11; UNE 217001; UNE 206007; PO 12.2; IEEE 1547 | – | – | – | – | – | – |
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
G6-GR1P(2.5-6)K-S(21A)
2.5 – 6 kWSingle-phaseIP66
View details
MOD 3-15KTL3-X-X2(Pro)
3 – 15 kWThree-phaseIP66
View details
MOD 3-33KTL3-X3
3 – 33 kWThree-phaseIP66
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.