SUN-3.6-10K-SG05LP1-EU-SM2-P
3.6 – 10 kWSingle-phaseIP65
View details
S6-EH1P(3.8-11.4)K-H-US
Hybrid inverter · Split-phase · 3.8 – 11.4 kW
3.8 – 11.4 kWSplit-phase2 – 4
Price on request
3.8 – 11.4 kWRated power
Split-phasePhase
2 – 4MPPT trackers
97 – 97.6 %Max. efficiency
Technical data
| S6-EH1P3.8K-H-US | S6-EH1P5K-H-US | S6-EH1P6K-H-US | S6-EH1P7.6K-H-US | S6-EH1P8K-H-US | S6-EH1P9.9K-H-US | S6-EH1P10K-H-US | S6-EH1P11.4K-H-US | |
|---|---|---|---|---|---|---|---|---|
| PV input | ||||||||
| Max. usable PV input power (W) | 6080 | 8000 | 9600 | 12160 | 12800 | 16000 | 16000 | 18240 |
| Max. PV input voltage (V) | 600 | |||||||
| Rated PV input voltage (V) | 380 | |||||||
| MPPT voltage range (V) | 80 – 520 | |||||||
| Start-up voltage (V) | 80 | |||||||
| Max. input current per MPPT (A) | 16 | |||||||
| Max. short-circuit current per MPPT (A) | 25.6 | |||||||
| Number of MPPT trackers | 2 | 3 | 3 | 4 | 4 | 4 | 4 | 4 |
| PV strings per MPPT | 1 | |||||||
| AC output | ||||||||
| Rated output power (W) | 3800 | 5000 | 6000 | 7600 | 8000 | 9990 | 10000 | 11400 |
| Max. apparent power (VA) | 3800 | 5000 | 6000 | 7600 | 8000 | 9990 | 10000 | 11400 |
| Rated AC voltage (V) | 240 | |||||||
| Rated AC output current (A) | 15.8 | 20.8 | 25 | 31.7 | 33.3 | 41.7 | 41.7 | 47.5 |
| Phase | Split-phase | |||||||
| Rated AC frequency (Hz) | 60 | |||||||
| Max. AC output current (A) | 15.8 | 20.8 | 25 | 31.7 | 33.3 | 41.7 | 41.7 | 47.5 |
| Total harmonic distortion (THDi) (%) | <3 | |||||||
| Power factor | >0.99 (0.8 leading to 0.8 lagging) | |||||||
| Backup output power (W) | 3800 | 5000 | 6000 | 7600 | 8000 | 9990 | 10000 | 11400 |
| Generator input | Yes | |||||||
| AC input voltage range (220 V / 240 V) (V) | 193.6-242 / 211-264 | |||||||
| Max. AC input current (220 V / 240 V) (A) | 25.9 / 23.8 | 34.1 / 31.2 | 40.9 / 37.5 | 51.8 / 47.6 | 54.4 / 49.9 | 68.2 / 62.6 | 68.2 / 62.6 | 77.7 / 71.3 |
| Grid pass-through current (220 V / 240 V) (A) | 17.3 / 15.8 | 22.7 / 20.8 | 27.3 / 25.0 | 34.5 / 31.7 | 36.4 / 33.3 | 45.5 / 41.7 | 45.5 / 41.7 | 51.8 / 47.5 |
| AC input frequency range (Hz) | 59.5-60.5 / 58.8-61.2 | |||||||
| Max. off-grid apparent power (10 s) (VA) | 6800 | 9000 | 10800 | 13700 | 14400 | 18000 | 18000 | 20500 |
| Grid / off-grid switching time (ms) | <10 | |||||||
| Off-grid output voltage range (220 V / 240 V) (V) | 193.6-242 / 211-264 | |||||||
| Off-grid frequency range (Hz) | 55 – 65 | |||||||
| Max. off-grid output overcurrent protection, 10 s (220 V / 240 V) (A) | 27.7 / 25.4 | 36.4 / 33.3 | 43.6 / 40 | 55.5 / 50.7 | 58.2 / 53.3 | 72.7 / 66.7 | 72.7 / 66.7 | 82.7 / 76 |
| Phase imbalance limit (%) | 100 | |||||||
| Backup port load type | Household loads and dedicated loads | |||||||
| Off-grid THDv (%) | <3 | |||||||
| Battery | ||||||||
| Battery type | High-voltage lithium battery | |||||||
| Battery voltage range (V) | 120 – 500 | |||||||
| Max. charge current (A) | 25 | 25 | 25 | 50 | 50 | 50 | 50 | 50 |
| Max. discharge current (A) | 25 | 25 | 25 | 50 | 50 | 50 | 50 | 50 |
| Battery communication | CAN / RS485 | |||||||
| Efficiency | ||||||||
| Max. efficiency (%) | 97 | 97 | – | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 |
| CEC efficiency (%) | 96.5 | 96.5 | – | 97 | 97 | 97 | 97 | 97 |
| Max. PV-to-battery charging efficiency (%) | 98.5 | |||||||
| Max. AC-to-battery charge/discharge efficiency (%) | 97.0 | |||||||
| Protection | ||||||||
| Protection functions | Ground fault detection; residual current detection; DC arc fault protection; DC reverse polarity protection; manual inverter bypass switch; rapid shutdown (NEC 2017); compatible with RSD receiver | |||||||
| Protection class / overvoltage category | I / II | |||||||
| General data | ||||||||
| Dimensions (W x H x D) (mm) | 490 × 720 × 220 | 490 × 720 × 220 | 490 × 720 × 220 | 560 × 750 × 220 | 560 × 750 × 220 | 560 × 750 × 220 | 560 × 750 × 220 | 560 × 750 × 220 |
| Weight (kg) | 23.78 | 23.78 | 23.78 | 32.54 | 32.54 | 32.54 | 32.54 | 32.54 |
| Topology | Transformerless | |||||||
| Night-time power consumption (W) | <20 | |||||||
| Operating temperature range (°C) | −25 – 60 | |||||||
| Protection degree (enclosure type) | TYPE 4X | |||||||
| Noise level (dB) | <30 | |||||||
| Cooling | Natural cooling | |||||||
| Installation | Wall-mounted | |||||||
| Max. operating altitude (m) | 4000 | |||||||
| DC port | Side and bottom (2 x 25.4 mm holes); spring terminals | |||||||
| AC port | Side and bottom (3 x 38.1 mm holes); spring terminals | |||||||
| High-precision meter | Optional | |||||||
| Communication | ||||||||
| Display | LED indicators, Bluetooth + app | |||||||
| Monitoring | Cloud monitoring platform (Modbus and API can be shared) | |||||||
| Communication interfaces | RS485; Cellular (optional); Wi-Fi (optional); LAN (optional) | |||||||
| Certifications | ||||||||
| Certifications and standards | UL1741SB; IEEE1547-2018; UL1699B; UL1998; FCC Part 15 Class B; California Rule 21; NEC 690.12-2020; CAN/CSA C22.2107.1-1; HECO Rule 14H; Luma Listed | |||||||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
SUN-3.6-10K-SG05LP1-EU-SM2-P
3.6 – 10 kWSingle-phaseIP65
View details
SPA 4000-10000TL3 BH-UP
4 – 10 kWThree-phaseIP65
View details
SPH 4000-10000TL3 BH-UP
4 – 10 kWThree-phaseIP65
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.