S6-EH2P(5-8)K02-SV-YD-L Hybrid inverter

S6-EH2P(5-8)K02-SV-YD-L

Hybrid inverter · Split-phase · 5 – 8 kW

5 – 8 kWSplit-phaseIP66
Price on request
5 – 8 kWRated power
Split-phasePhase
2MPPT trackers
95.4 %Max. efficiency

Technical data

S6-EH2P5K02-SV-YD-LS6-EH2P6K02-SV-YD-LS6-EH2P7.5K02-SV-YD-LS6-EH2P8K02-SV-YD-L
PV input
Max. PV input power (W)10000120001600016000
Max. usable PV input power (W)800096001280012800
Max. PV input voltage (V)500
Rated PV input voltage (V)330
MPPT voltage range (V)90 – 435
Start-up voltage (V)90
Max. input current per MPPT (A)21424242
Max. short-circuit current per MPPT (A)24484848
Number of MPPT trackers2
Max. input current per string (A)21
Max. number of PV input strings2344
AC output
Rated output power (W)5000600075008000
Max. apparent power (VA)5500660075008800
Rated AC voltage (V)240
Rated AC output current (A)20.82531.333.3
PhaseSplit-phase
Rated AC frequency (Hz)50/60
Total harmonic distortion (THDi) (%)<3
Power factor> 0.99 (0.8 leading to 0.8 lagging)
Backup output power (W)5000600075008000
Peak (surge) power (W)10000120001500016000
Generator inputYes
Max. parallel units6
Grid voltage configurationsL+N+PE / 2L+PE, 220 V; L1/L2/N(PE), 120 (L-N) / 240 (L1-L2) VAC; L1/L2/N(PE), 127 (L-N) / 220 (L1-L2) VAC
Rated grid output current at 220 V (A)22.727.334.136.4
Max. grid input power (W)770088001100011000
Grid input voltage range (V)187 – 253
Max. grid input current (A)35405050
Backup rated output voltageL1/L2/N(PE), 127 V / 220 V; 120 (L-N) / 240 (L1-L2) VAC; 127 (L-N) / 220 (L1-L2) VAC
Backup rated output frequency (Hz)50/60
Backup rated output current (at 240 V / 220 V) (A)20.8 / 22.725 / 27.331.3 / 34.133.3 / 36.4
Max. bypass current (A)35405050
Backup THDv (%)<3
On/off-grid switching time<10 ms
Generator max. input power (W)5000600075008000
Generator rated input current (at 240 V / 220 V) (A)20.8 / 22.725 / 27.331.3 / 34.133.3 / 36.4
Battery
Battery typeLithium or lead-acid
Battery voltage range (V)40 – 60
Max. charge current (A)112135190190
Max. discharge current (A)112135190190
Number of battery ports / BMS ports1 / 1
Battery communicationCAN / RS485
Efficiency
Max. efficiency (%)95.4
European efficiency (%)94.3
Battery charging efficiency (%)95.0
Battery discharging efficiency (%)93.7
Protection
Protection functionsSurge (lightning) protection; AC output overcurrent protection; Insulation resistance protection; Residual current (RCD) detection; Integrated PV switch; DC reverse polarity protection; DC arc fault protection; Anti-islanding protection
Protection class / overvoltage categoryClass I / OVC II (PV and battery ports), OVC III (grid, off-grid and generator ports)
General data
Dimensions (W x H x D) (mm)390 × 620 × 237
Weight (kg)28.8
Ingress protection (IP rating)IP66
Operating temperature range (°C)−25 – 60
Relative humidity (%)0 – 100
Max. operating altitude (m)4000
CoolingSmart redundant air cooling
Noise level (dB)<55
TopologyNon-isolated (PV), isolated (battery)
Self-consumption (W)<20
Max. single-phase load capability50% of rated power
PV portMC4 quick-connect plug
Battery portScrew terminal
AC portScrew terminal
Communication
Display7-inch LCD display, Bluetooth + app
Communication interfacesWi-Fi; LAN; Bluetooth; CAN-BMS; CAN-Parallel x 2; RS485-Meter; RS485; DRM; DI; DO x 2; 4G (optional)
Certifications
Certifications and standardsIEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2; UL 1741; UL 1699B; FCC
Grid codesInmetro140; IEEE 1547

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote