S6-EH2P(5-8)K02-SV-YD-L
5 – 8 kWSplit-phaseIP66
View details
SUN-5-12K-SG01HP3-EU-DM2
Hybrid inverter · Three-phase · 5 – 12 kW
5 – 12 kWThree-phaseIP65
Price on request
5 – 12 kWRated power
Three-phasePhase
2MPPT trackers
97.6 %Max. efficiency
Technical data
| SUN-5K-SG01HP3-EU-DM2 | SUN-6K-SG01HP3-EU-DM2 | SUN-8K-SG01HP3-EU-DM2 | SUN-10K-SG01HP3-EU-DM2 | SUN-12K-SG01HP3-EU-DM2 | |
|---|---|---|---|---|---|
| PV input | |||||
| Max. PV input power (W) | 10000 | 12000 | 16000 | 20000 | 24000 |
| Max. usable PV input power (W) | 8000 | 9600 | 12800 | 16000 | 19200 |
| Max. PV input voltage (V) | 1000 | ||||
| Rated PV input voltage (V) | 600 | ||||
| MPPT voltage range (V) | 150 – 850 | ||||
| Start-up voltage (V) | 180 | ||||
| Max. input current per MPPT (A) | 18 | ||||
| Max. short-circuit current per MPPT (A) | 27 | ||||
| Number of MPPT trackers | 2 | ||||
| PV strings per MPPT | 1 | ||||
| AC output | |||||
| Rated output power (W) | 5000 | 6000 | 8000 | 10000 | 12000 |
| Max. apparent power (VA) | 5500 | 6600 | 8800 | 11000 | 13200 |
| Rated AC voltage (V) | 400 | ||||
| Rated AC output current (A) | 7.3 | 8.7 | 11.6 | 14.5 | 17.4 |
| Max. AC output current (A) | 8 | 9.6 | 12.8 | 16 | 19.2 |
| Phase | Three-phase | ||||
| Rated AC frequency (Hz) | 50/60 | ||||
| Total harmonic distortion (THDi) (%) | <3 | ||||
| Power factor | 0.8 leading to 0.8 lagging | ||||
| Peak (surge) power (W) | 7500 | 9000 | 12000 | 15000 | 18000 |
| Generator input | Yes | ||||
| Max. parallel units | 10 | ||||
| Max. continuous AC pass-through current (grid to load) (A) | 35 | ||||
| Grid connection type | 3L+N+PE | ||||
| DC injection current | <0.5% In | ||||
| Unbalanced output capability (%) | 100 | ||||
| Battery | |||||
| Battery type | Lithium-ion | ||||
| Battery voltage range (V) | 160 – 700 | ||||
| Max. charge current (A) | 37 | ||||
| Max. discharge current (A) | 37 | ||||
| Charging strategy for Li-ion battery | Self-adaption to BMS | ||||
| Number of battery inputs | 1 | ||||
| Efficiency | |||||
| Max. efficiency (%) | 97.6 | ||||
| European efficiency (%) | 97 | ||||
| MPPT efficiency (%) | >99 | ||||
| Protection | |||||
| Protection functions | DC reverse polarity protection; AC output overcurrent protection; Thermal protection; AC output overvoltage protection; AC output short circuit protection; DC component monitoring; Arc fault circuit interrupter (AFCI) (optional); Anti-islanding protection; DC switch; Insulation impedance detection; Residual current detection | ||||
| Surge protection level | Type II (DC), Type II (AC) | ||||
| General data | |||||
| Dimensions (W x H x D) (mm) | 376 × 470 × 244.5 | ||||
| Weight (kg) | 24 | ||||
| Ingress protection (IP rating) | IP65 | ||||
| Operating temperature range (°C) | −40 – 60 | ||||
| Relative humidity (%) | 0 – 100 | ||||
| Max. operating altitude (m) | 2000 | ||||
| Cooling | Natural cooling | Natural cooling | Natural cooling | Natural cooling | Intelligent air cooling |
| Noise level (dB) | ≤45 | ||||
| Topology | Non-isolated | ||||
| Warranty (years) | 5 – 10 | ||||
| Overvoltage category | OVC II (DC), OVC III (AC) | ||||
| Communication | |||||
| Display | LCD + LED | ||||
| Communication interfaces | RS485; RS232; CAN | ||||
| Monitoring | GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional) | ||||
| Certifications | |||||
| Certifications and standards | IEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2 | ||||
| Grid codes | IEC 61727; IEC 62116; CEI 0-21; EN 50549; NRS 097; RD 140; UNE 217002; OVE-Richtlinie R25; G99; VDE-AR-N 4105 | ||||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
S6-EH2P(5-8)K02-SV-YD-L
5 – 8 kWSplit-phaseIP66
View details
SUN-5-12K-SG02HP3-EU-DM2
5 – 12 kWThree-phaseIP65
View details
SUN-5-12K-SG02LP2-US-AM2-AM3
5 – 12 kWSplit-phaseIP65
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.