SPM 2500-6000TL-HU-HU2 Hybrid inverter

SPM 2500-6000TL-HU-HU2

Hybrid inverter · Single-phase · 2.5 – 6 kW

2.5 – 6 kWSingle-phaseIP65
Price on request
2.5 – 6 kWRated power
Single-phasePhase
2MPPT trackers
97.5 – 98.1 %Max. efficiency

Technical data

SPM 2500TL-HU2SPM 3000TL-HU2SPM 3600TL-HU2SPM 5000TL-HU2SPM 6000TL-HU2SPM 3000TL-HUSPM 3600TL-HUSPM 4000TL-HUSPM 4600TL-HUSPM 5000TL-HUSPM 5500TL-HUSPM 6000TL-HU
PV input
Max. PV input power (W)400048005760800096006000720080009200100001100012000
Max. usable PV input power (W)–––––4500540060006900750082509000
Max. input power per MPPT (W)–––––4500450045004500450045004500
Max. PV input voltage (V)550550550550550600600600600600600600
Start-up voltage (V)7070707070130130130130130130130
MPPT voltage range (V)80 – 52580 – 52580 – 52580 – 52580 – 525150 – 550150 – 550150 – 550150 – 550150 – 550150 – 550150 – 550
Number of MPPT trackers2
PV strings per MPPT1
Max. input current per MPPT (A)181818181822222222222222
Max. short-circuit current per MPPT (A)27.5
AC output
Nominal AC input power (W)250030003600500060003000360040004600500055006000
Nominal AC input voltage (V)220 / 230 / 240
Nominal AC input current (A)10.913.115.721.826.113.115.717.42021.82426.1
Max. grid passthrough current (A)12.51518253016.62022.225.527.730.533.3
Generator inputYes
Max. generator input power (W)9200
Rated output power (W)250030003600500060003000360040004600500055006000
Max. apparent power (VA)250030003600500060003000360040004600500055006000
Rated AC voltage (V)230
Nominal AC voltage options (V)220 / 230 / 240
PhaseSingle-phase
Rated AC frequency (Hz)50/60
Max. AC output current (A)10.913.115.721.826.113.115.717.42021.82426.1
Power factor0.8 leading to 0.8 lagging (adjustable)
Total harmonic distortion (THDi) (%)<3
Max. parallel units999996666666
Backup output power (W)250030003600500060003000360040004600500055006000
Backup nominal output voltage (V)220 / 230 / 240220 / 230 / 240220 / 230 / 240220 / 230 / 240220 / 230 / 240230230230230230230230
Backup nominal output frequency (Hz)50 / 60
Backup switch time (ms)<10
Peak (surge) power (W)50006000720010000120006000720080009200100001100012000
Backup overload capability200% of full load for 10 s200% of full load for 10 s200% of full load for 10 s200% of full load for 10 s200% of full load for 10 s200% of full load for 5 s200% of full load for 5 s200% of full load for 5 s200% of full load for 5 s200% of full load for 5 s200% of full load for 5 s200% of full load for 5 s
Battery
Battery typeLithium battery / Lead-acid battery
Battery voltage range (V)40 – 60
Max. charge current (A)6070901201407090100110120130140
Max. discharge current (A)6070901201407090100110120130140
Max. charge power (W)250030003600500060003000360040004600500055006000
Max. discharge power (W)250030003600500060003000360040004600500055006000
Efficiency
Max. efficiency (%)97.597.597.597.597.598.198.198.198.198.198.198.1
European efficiency (%)96.696.696.696.696.697.697.697.697.697.697.697.6
MPPT efficiency (%)99
Protection
Protection functionsPV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II)PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II)
General data
Dimensions (W x H x D) (mm)345 × 450 × 255345 × 450 × 255345 × 450 × 255345 × 450 × 255345 × 450 × 255330 × 580 × 232330 × 580 × 232330 × 580 × 232330 × 580 × 232330 × 580 × 232330 × 580 × 232330 × 580 × 232
Weight (kg)161616161626262626262626
Gross weight (kg)2020202020–––––––
Ingress protection (IP rating)IP65
Operating temperature range (°C)−25 – 60
Power derating above (°C)45
Relative humidity (%)0 – 100
Max. operating altitude (m)<2000
CoolingSmart fan coolingSmart fan coolingSmart fan coolingSmart fan coolingSmart fan coolingNatural convectionNatural convectionNatural convectionNatural convectionNatural convectionNatural convectionNatural convection
Noise level (dB)–––––≤30≤30≤30≤30≤30≤30≤30
Self-consumption (W)–––––<60<60<60<60<60<60<60
TopologyTransformerless
Warranty (years)5555510101010101010
Communication
DisplayLCD touch screen
Communication interfacesRS485; CAN; USB; Wi-FiRS485; CAN; USB; Wi-FiRS485; CAN; USB; Wi-FiRS485; CAN; USB; Wi-FiRS485; CAN; USB; Wi-FiRS485; CAN; USB; Wi-Fi; LANRS485; CAN; USB; Wi-Fi; LANRS485; CAN; USB; Wi-Fi; LANRS485; CAN; USB; Wi-Fi; LANRS485; CAN; USB; Wi-Fi; LANRS485; CAN; USB; Wi-Fi; LANRS485; CAN; USB; Wi-Fi; LAN
Certifications
Certifications and standardsCE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

User manuals

  • SPM 2500-6000TL-HU-HU2 user manual (English)PDF · 4.9 MBDownload

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote