MIN 2500-6000TL-XH2
2.5 – 6 kWSingle-phaseIP66
View details
SPM 2500-6000TL-HU-HU2
Hybrid inverter · Single-phase · 2.5 – 6 kW
2.5 – 6 kWSingle-phaseIP65
Price on request
2.5 – 6 kWRated power
Single-phasePhase
2MPPT trackers
97.5 – 98.1 %Max. efficiency
Technical data
| SPM 2500TL-HU2 | SPM 3000TL-HU2 | SPM 3600TL-HU2 | SPM 5000TL-HU2 | SPM 6000TL-HU2 | SPM 3000TL-HU | SPM 3600TL-HU | SPM 4000TL-HU | SPM 4600TL-HU | SPM 5000TL-HU | SPM 5500TL-HU | SPM 6000TL-HU | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PV input | ||||||||||||
| Max. PV input power (W) | 4000 | 4800 | 5760 | 8000 | 9600 | 6000 | 7200 | 8000 | 9200 | 10000 | 11000 | 12000 |
| Max. usable PV input power (W) | – | – | – | – | – | 4500 | 5400 | 6000 | 6900 | 7500 | 8250 | 9000 |
| Max. input power per MPPT (W) | – | – | – | – | – | 4500 | 4500 | 4500 | 4500 | 4500 | 4500 | 4500 |
| Max. PV input voltage (V) | 550 | 550 | 550 | 550 | 550 | 600 | 600 | 600 | 600 | 600 | 600 | 600 |
| Start-up voltage (V) | 70 | 70 | 70 | 70 | 70 | 130 | 130 | 130 | 130 | 130 | 130 | 130 |
| MPPT voltage range (V) | 80 – 525 | 80 – 525 | 80 – 525 | 80 – 525 | 80 – 525 | 150 – 550 | 150 – 550 | 150 – 550 | 150 – 550 | 150 – 550 | 150 – 550 | 150 – 550 |
| Number of MPPT trackers | 2 | |||||||||||
| PV strings per MPPT | 1 | |||||||||||
| Max. input current per MPPT (A) | 18 | 18 | 18 | 18 | 18 | 22 | 22 | 22 | 22 | 22 | 22 | 22 |
| Max. short-circuit current per MPPT (A) | 27.5 | |||||||||||
| AC output | ||||||||||||
| Nominal AC input power (W) | 2500 | 3000 | 3600 | 5000 | 6000 | 3000 | 3600 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Nominal AC input voltage (V) | 220 / 230 / 240 | |||||||||||
| Nominal AC input current (A) | 10.9 | 13.1 | 15.7 | 21.8 | 26.1 | 13.1 | 15.7 | 17.4 | 20 | 21.8 | 24 | 26.1 |
| Max. grid passthrough current (A) | 12.5 | 15 | 18 | 25 | 30 | 16.6 | 20 | 22.2 | 25.5 | 27.7 | 30.5 | 33.3 |
| Generator input | Yes | |||||||||||
| Max. generator input power (W) | 9200 | |||||||||||
| Rated output power (W) | 2500 | 3000 | 3600 | 5000 | 6000 | 3000 | 3600 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Max. apparent power (VA) | 2500 | 3000 | 3600 | 5000 | 6000 | 3000 | 3600 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Rated AC voltage (V) | 230 | |||||||||||
| Nominal AC voltage options (V) | 220 / 230 / 240 | |||||||||||
| Phase | Single-phase | |||||||||||
| Rated AC frequency (Hz) | 50/60 | |||||||||||
| Max. AC output current (A) | 10.9 | 13.1 | 15.7 | 21.8 | 26.1 | 13.1 | 15.7 | 17.4 | 20 | 21.8 | 24 | 26.1 |
| Power factor | 0.8 leading to 0.8 lagging (adjustable) | |||||||||||
| Total harmonic distortion (THDi) (%) | <3 | |||||||||||
| Max. parallel units | 9 | 9 | 9 | 9 | 9 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
| Backup output power (W) | 2500 | 3000 | 3600 | 5000 | 6000 | 3000 | 3600 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Backup nominal output voltage (V) | 220 / 230 / 240 | 220 / 230 / 240 | 220 / 230 / 240 | 220 / 230 / 240 | 220 / 230 / 240 | 230 | 230 | 230 | 230 | 230 | 230 | 230 |
| Backup nominal output frequency (Hz) | 50 / 60 | |||||||||||
| Backup switch time (ms) | <10 | |||||||||||
| Peak (surge) power (W) | 5000 | 6000 | 7200 | 10000 | 12000 | 6000 | 7200 | 8000 | 9200 | 10000 | 11000 | 12000 |
| Backup overload capability | 200% of full load for 10 s | 200% of full load for 10 s | 200% of full load for 10 s | 200% of full load for 10 s | 200% of full load for 10 s | 200% of full load for 5 s | 200% of full load for 5 s | 200% of full load for 5 s | 200% of full load for 5 s | 200% of full load for 5 s | 200% of full load for 5 s | 200% of full load for 5 s |
| Battery | ||||||||||||
| Battery type | Lithium battery / Lead-acid battery | |||||||||||
| Battery voltage range (V) | 40 – 60 | |||||||||||
| Max. charge current (A) | 60 | 70 | 90 | 120 | 140 | 70 | 90 | 100 | 110 | 120 | 130 | 140 |
| Max. discharge current (A) | 60 | 70 | 90 | 120 | 140 | 70 | 90 | 100 | 110 | 120 | 130 | 140 |
| Max. charge power (W) | 2500 | 3000 | 3600 | 5000 | 6000 | 3000 | 3600 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Max. discharge power (W) | 2500 | 3000 | 3600 | 5000 | 6000 | 3000 | 3600 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Efficiency | ||||||||||||
| Max. efficiency (%) | 97.5 | 97.5 | 97.5 | 97.5 | 97.5 | 98.1 | 98.1 | 98.1 | 98.1 | 98.1 | 98.1 | 98.1 |
| European efficiency (%) | 96.6 | 96.6 | 96.6 | 96.6 | 96.6 | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 |
| MPPT efficiency (%) | 99 | |||||||||||
| Protection | ||||||||||||
| Protection functions | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; AFCI protection (optional); Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II) | PV switch; AC over-current protection; AC over-voltage protection; Ground fault monitoring; Grid monitoring; Anti-islanding protection; Residual-current monitoring unit; Insulation resistance monitoring; Surge protection (DC Type II / AC Type II) |
| General data | ||||||||||||
| Dimensions (W x H x D) (mm) | 345 × 450 × 255 | 345 × 450 × 255 | 345 × 450 × 255 | 345 × 450 × 255 | 345 × 450 × 255 | 330 × 580 × 232 | 330 × 580 × 232 | 330 × 580 × 232 | 330 × 580 × 232 | 330 × 580 × 232 | 330 × 580 × 232 | 330 × 580 × 232 |
| Weight (kg) | 16 | 16 | 16 | 16 | 16 | 26 | 26 | 26 | 26 | 26 | 26 | 26 |
| Gross weight (kg) | 20 | 20 | 20 | 20 | 20 | – | – | – | – | – | – | – |
| Ingress protection (IP rating) | IP65 | |||||||||||
| Operating temperature range (°C) | −25 – 60 | |||||||||||
| Power derating above (°C) | 45 | |||||||||||
| Relative humidity (%) | 0 – 100 | |||||||||||
| Max. operating altitude (m) | <2000 | |||||||||||
| Cooling | Smart fan cooling | Smart fan cooling | Smart fan cooling | Smart fan cooling | Smart fan cooling | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection |
| Noise level (dB) | – | – | – | – | – | ≤30 | ≤30 | ≤30 | ≤30 | ≤30 | ≤30 | ≤30 |
| Self-consumption (W) | – | – | – | – | – | <60 | <60 | <60 | <60 | <60 | <60 | <60 |
| Topology | Transformerless | |||||||||||
| Warranty (years) | 5 | 5 | 5 | 5 | 5 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Communication | ||||||||||||
| Display | LCD touch screen | |||||||||||
| Communication interfaces | RS485; CAN; USB; Wi-Fi | RS485; CAN; USB; Wi-Fi | RS485; CAN; USB; Wi-Fi | RS485; CAN; USB; Wi-Fi | RS485; CAN; USB; Wi-Fi | RS485; CAN; USB; Wi-Fi; LAN | RS485; CAN; USB; Wi-Fi; LAN | RS485; CAN; USB; Wi-Fi; LAN | RS485; CAN; USB; Wi-Fi; LAN | RS485; CAN; USB; Wi-Fi; LAN | RS485; CAN; USB; Wi-Fi; LAN | RS485; CAN; USB; Wi-Fi; LAN |
| Certifications | ||||||||||||
| Certifications and standards | CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000 | CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000 | CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000 | CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000 | CE; IEC 62116; IEC 61683; IEC 61727; IEC 60068; NRS 097; EN 61000 | EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727 | EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727 | EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727 | EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727 | EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727 | EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727 | EN 50549; CE-EMC; CE-LVD; IEC 62116; IEC 61727 |
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
MIN 2500-6000TL-XH2
2.5 – 6 kWSingle-phaseIP66
View details
G6-EH1P(3-10)K-L-PLUS
3 – 10 kWSingle-phaseIP66
View details
MIN 3000-11400TL-XH-US
3 – 11.4 kWSplit-phaseIP65
View details
Request a quotation