SUN-3.6-6.2K-G05P1-EU-AM2 String inverter

SUN-3.6-6.2K-G05P1-EU-AM2

String inverter · Single-phase · 3.6 – 6.2 kW

3.6 – 6.2 kWSingle-phaseIP65
Price on request
3.6 – 6.2 kWRated power
Single-phasePhase
2MPPT trackers
97.3 – 97.5 %Max. efficiency

Technical data

SUN-3.6K-G05P1-EU-AM2SUN-4K-G05P1-EU-AM2SUN-4.2K-G05P1-EU-AM2SUN-4.6K-G05P1-EU-AM2SUN-5K-G05P1-EU-AM2SUN-5.2K-G05P1-EU-AM2SUN-6K-G05P1-EU-AM2SUN-6.2K-G05P1-EU-AM2
PV input
Max. PV input power (W)54006000630069007500780090009300
Max. PV input voltage (V)550
Start-up voltage (V)80
MPPT voltage range (V)70 – 500
Rated PV input voltage (V)360
Max. input current per MPPT (A)18
Max. short-circuit current per MPPT (A)27
Number of MPPT trackers2
PV strings per MPPT1
AC output
Rated output power (W)36004000420046005000520060006200
Max. apparent power (VA)39604400462050605500572066006820
Rated AC voltage (V)230
Nominal AC voltage options (V)220 / 230
AC voltage range (relative to rated voltage)0.85-1.1 Un
Rated AC output current (A)15.717.418.32021.822.726.127
PhaseSingle-phase
Rated AC frequency (Hz)50/60
AC grid frequency range (50 Hz / 60 Hz) (Hz)45-55 / 55-65
Max. AC output current (A)17.319.220.1222424.928.729.7
Power factor0.8 leading to 0.8 lagging (adjustable)
Total harmonic distortion (THDi) (%)<3
DC injection current (% of rated current) (%)<0.5
AC grid connection typeL/N/PE
Efficiency
Max. efficiency (%)97.397.597.597.597.597.597.597.5
European efficiency (%)96.997979797979797
MPPT efficiency (%)>99
Protection
Protection functionsDC reverse polarity protection; AC output overcurrent protection; AC output overvoltage protection; AC output short-circuit protection; Thermal protection; Insulation impedance detection; DC component monitoring; Arc fault circuit interrupter (AFCI, optional); Anti-islanding protection; Residual current detection; Surge protection (DC Type II / AC Type II); DC switch
Anti-PID functionOptional
General data
Dimensions (W x H x D) (mm)305 × 280 × 180
Weight (kg)7.7
Ingress protection (IP rating)IP65
Operating temperature range (°C)−25 – 60
Power derating above (°C)45
Relative humidity (%)0 – 100
Max. operating altitude (m)3000
Noise level (dB)≤35
TopologyNon-isolated
CoolingNatural cooling
Warranty (years)5
Overvoltage categoryOVC II (DC); OVC III (AC)
Communication
Communication interfacesRS485; RS232
MonitoringGPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)
String intelligent monitoringOptional
Certifications
Certifications and standardsIEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2
Grid codesIEC 61727; IEC 62116; EN 50549; NRS 097; RD 140; UNE 217002; G98; G99

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote