WIT 4-25K-XHU
4 – 25 kWThree-phaseIP66
View details
SUN-4.95-8K-SG02HP2-JP-FM4
Hybrid inverter · Split-phase · 4.95 – 8 kW
4.95 – 8 kWSplit-phaseIP65
Price on request
4.95 – 8 kWRated power
Split-phasePhase
4MPPT trackers
IP65Protection class
Technical data
| SUN-4.95K-SG02HP2-JP-FM4 | SUN-5.5K-SG02HP2-JP-FM4 | SUN-8K-SG02HP2-JP-FM4 | |
|---|---|---|---|
| PV input | |||
| Max. PV input power (W) | 10000 | 11000 | 16000 |
| Max. usable PV input power (W) | 8000 | 8800 | 12600 |
| Max. PV input voltage (V) | 500 | ||
| Rated PV input voltage (V) | 350 | ||
| MPPT voltage range (V) | 50 – 450 | ||
| Start-up voltage (V) | 70 | ||
| Max. input current per MPPT (A) | 20 | ||
| Max. short-circuit current per MPPT (A) | 30 | ||
| Number of MPPT trackers | 4 | ||
| PV strings per MPPT | 1 | ||
| Full-load MPPT voltage range (V) | 250 – 450 | ||
| AC output | |||
| Rated output power (W) | 4950 | 5500 | 8000 |
| Max. apparent power (VA) | 5440 | 6050 | 8800 |
| Rated AC voltage (V) | 202 | ||
| Rated AC output current (A) | 24.6 | 27.3 | 39.7 |
| Max. AC output current (A) | 27 | 30 | 43.6 |
| Phase | Split-phase | ||
| Rated AC frequency (Hz) | 50/60 | ||
| Total harmonic distortion (THDi) (%) | <3 | ||
| Power factor | 0.8 leading to 0.8 lagging | ||
| Peak (surge) power (W) | 7425 | 8250 | 12000 |
| Rated output voltage (L-N / L-L) (V) | 101/202 | ||
| Electrical system | Single-phase three-wire (supports 101 V and 202 V) | ||
| Max. continuous AC bus pass-through current (grid to load) (A) | 80 | ||
| Grid DC component | <0.5% In | ||
| Battery | |||
| Battery type | Lead-acid or lithium-ion | ||
| Battery voltage range (V) | 80 – 500 | ||
| Max. charge current (A) | 50 | ||
| Max. discharge current (A) | 50 | ||
| Battery charging method | Self-adaptation to BMS | ||
| Number of battery inputs | 1 | ||
| Protection | |||
| Protection functions | Integrated DC reverse polarity protection; AC output overcurrent protection; Overheat protection; AC output overvoltage protection; AC output short circuit protection; DC component detection; Overvoltage load reduction protection; Ground fault current detection; Arc fault circuit interrupter (optional); Power system monitoring and control; Islanding detection; Ground fault detection; DC input switch; DC terminal insulation resistance detection; Residual current (RCD) detection; Surge protection | ||
| General data | |||
| Dimensions (W x H x D) (mm) | 423 × 570 × 256.5 | ||
| Weight (kg) | 32 | ||
| Ingress protection (IP rating) | IP65 | ||
| Operating temperature range (°C) | −40 – 60 | ||
| Relative humidity (%) | 0 – 100 | ||
| Max. operating altitude (m) | 3000 | ||
| Cooling | Natural air cooling | ||
| Noise level (dB) | ≤50 | ||
| Topology | Non-isolated | ||
| Warranty (years) | 10 | ||
| Overvoltage category | OVC II (DC), OVC II (AC) | ||
| Surge protection level | Type III | ||
| Certifications | |||
| Certifications and standards | S-JET | ||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
WIT 4-25K-XHU
4 – 25 kWThree-phaseIP66
View details
S6-EA3P(5-10)KAA-NV-ND-H
5 – 10 kWThree-phaseIP66
View details
S6-EH2P(5-8)K02-SV-YD-L
5 – 8 kWSplit-phaseIP66
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.