SUN-60-80K-SG02HP3-EU-EM6 Hybrid inverter

SUN-60-80K-SG02HP3-EU-EM6

Hybrid inverter · Three-phase · 60 – 80 kW

60 – 80 kWThree-phaseIP65
Price on request
60 – 80 kWRated power
Three-phasePhase
6MPPT trackers
98.7 %Max. efficiency

Technical data

SUN-60K-SG02HP3-EU-EM6SUN-70K-SG02HP3-EU-EM6SUN-75K-SG02HP3-EU-EM6SUN-80K-SG02HP3-EU-EM6
PV input
Max. PV input power (W)120000140000150000160000
Max. usable PV input power (W)96000112000120000128000
Max. PV input voltage (V)1000
Rated PV input voltage (V)650
MPPT voltage range (V)150 – 850
Start-up voltage (V)180
Max. input current per MPPT (A)36
Max. short-circuit current per MPPT (A)54
Number of MPPT trackers6
PV strings per MPPT2
AC output
Rated output power (W)60000700007500080000
Max. apparent power (VA)66000770008250088000
Rated AC voltage (V)400
Rated AC output current (A)87101.5108.7116
PhaseThree-phase
Rated AC frequency (Hz)50/60
Max. AC output current (A)95.7111.6119.6127.6
Total harmonic distortion (THDi) (%)<3
Power factor0.8 leading to 0.8 lagging
Peak (surge) power (W)90000105000112500120000
Generator inputYes
Max. parallel units10
Peak power duration (off-grid)10 s
Rated AC voltage options (V)220/380; 230/400
AC voltage range0.85 Un-1.1 Un
Grid connection type3L+N+PE
Grid frequency range (50 Hz / 60 Hz) (Hz)45-55 / 55-65
Max. continuous AC passthrough (grid to load) (A)200
DC injection current<0.5% In
AC coupling (retrofit of existing solar systems)Yes
Battery
Battery typeLithium-ion
Battery voltage range (V)160 – 1000
Max. charge current (A)160
Max. discharge current (A)160
Max. charge/discharge current per battery input (A)80
Number of battery inputs2
Charging strategy for Li-ion batterySelf-adaption to BMS
Charge/discharge time periods6
Efficiency
Max. efficiency (%)98.7
European efficiency (%)98.1
MPPT efficiency (%)>99
Protection
Protection functionsDC reverse polarity protection; AC output overcurrent protection; Thermal protection; AC output overvoltage protection; AC output short-circuit protection; DC component monitoring; Arc fault circuit interrupter (AFCI) (optional); Anti-islanding protection; DC switch; Insulation impedance detection; Residual current detection
Surge protection levelType II (DC), Type II (AC)
General data
Dimensions (W x H x D) (mm)606 × 927 × 314
Weight (kg)105
Ingress protection (IP rating)IP65
Operating temperature range (°C)−40 – 60
Relative humidity (%)0 – 100
Max. operating altitude (m)3000
CoolingSmart cooling
Noise level (dB)≤65
TopologyNon-isolated
Overvoltage categoryOVC II (DC), OVC III (AC)
Warranty (years)5 – 10
Communication
DisplayLCD + LED
Communication interfacesRS485; RS232; CAN
MonitoringGPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)
Certifications
Certifications and standardsIEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2
Grid codesIEC 61727; IEC 62116; CEI 0-21; EN 50549; NRS 097; RD 140; UNE 217002; OVE-Richtlinie R25; G99; VDE-AR-N 4105

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote