S6-EH3P(7-9)K02-LV-YD-L
7 – 9 kWThree-phaseIP66
View details
SUN-7-10K-SG05LP1-EU-SM2
Hybrid inverter · Single-phase · 7 – 10 kW
7 – 10 kWSingle-phaseIP65
Price on request
7 – 10 kWRated power
Single-phasePhase
2MPPT trackers
97.6 %Max. efficiency
Technical data
| SUN-7K-SG05LP1-EU-SM2 | SUN-7.6K-SG05LP1-EU-SM2 | SUN-8K-SG05LP1-EU-SM2 | SUN-10K-SG05LP1-EU-SM2 | |
|---|---|---|---|---|
| PV input | ||||
| Max. PV input power (W) | 14000 | 15200 | 16000 | 20000 |
| Max. usable PV input power (W) | 11200 | 12160 | 12800 | 16000 |
| Max. PV input voltage (V) | 500 | |||
| Rated PV input voltage (V) | 370 | |||
| MPPT voltage range (V) | 150 – 425 | |||
| Start-up voltage (V) | 125 | |||
| Max. input current per MPPT (A) | 26 | |||
| Max. short-circuit current per MPPT (A) | 34 | |||
| Number of MPPT trackers | 2 | |||
| PV strings per MPPT | 2 | |||
| AC output | ||||
| Rated output power (W) | 7000 | 7600 | 8000 | 10000 |
| Max. apparent power (VA) | 7700 | 8360 | 8800 | 11000 |
| Rated AC voltage (V) | 230 | |||
| Rated AC output current (A) | 30.5 | 33.1 | 34.8 | 43.5 |
| Max. AC output current (A) | 33.5 | 36.4 | 38.3 | 47.9 |
| Phase | Single-phase | |||
| Rated AC frequency (Hz) | 50/60 | |||
| Total harmonic distortion (THDi) (%) | <3 | |||
| Power factor | 0.8 leading to 0.8 lagging | |||
| Peak (surge) power (W) | 14000 | 15200 | 16000 | 20000 |
| Peak power duration (off-grid) (s) | 10 | |||
| Rated AC voltage options (V) | 220; 230 | |||
| AC voltage range | 0.85 Un-1.1 Un | |||
| Grid connection type | L+N+PE | |||
| Grid frequency range (50 Hz / 60 Hz) (Hz) | 45-55 / 55-65 | |||
| Max. continuous AC passthrough (grid to load) (A) | 50 | |||
| DC injection current | <0.5% In | |||
| Generator input | Yes | |||
| Max. parallel units | 16 | |||
| Battery | ||||
| Battery type | Lead-acid or lithium-ion | |||
| Battery voltage range (V) | 40 – 60 | |||
| Max. charge current (A) | 175 | 190 | 190 | 210 |
| Max. discharge current (A) | 175 | 190 | 190 | 210 |
| Charging strategy for Li-ion battery | Self-adaption to BMS | |||
| Number of battery inputs | 1 | |||
| Time periods for battery charging/discharging | 6 | |||
| Efficiency | ||||
| Max. efficiency (%) | 97.6 | |||
| European efficiency (%) | 96.5 | |||
| MPPT efficiency (%) | >99 | |||
| Protection | ||||
| Protection functions | DC reverse polarity protection; AC output overcurrent protection; Thermal protection; AC output overvoltage protection; AC output short-circuit protection; DC component monitoring; Arc fault circuit interrupter (AFCI) (optional); Anti-islanding protection; DC switch; Insulation impedance detection; Residual current detection | |||
| Surge protection level | Type II (DC), Type II (AC) | |||
| General data | ||||
| Dimensions (W x H x D) (mm) | 366 × 589.5 × 237 | |||
| Weight (kg) | 26.8 | |||
| Ingress protection (IP rating) | IP65 | |||
| Operating temperature range (°C) | −40 – 60 | |||
| Relative humidity (%) | 0 – 100 | |||
| Max. operating altitude (m) | 2000 | |||
| Cooling | Intelligent air cooling | |||
| Noise level (dB) | <45 | |||
| Topology | Non-isolated | |||
| Overvoltage category | OVC II (DC), OVC III (AC) | |||
| Warranty (years) | 5 – 10 | |||
| Communication | ||||
| Display | Colorful touch LCD | |||
| Communication interfaces | Wi-Fi; RS485; CAN | |||
| Certifications | ||||
| Certifications and standards | IEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2 | |||
| Grid codes | IEC 61727; IEC 62116; CEI 0-21; EN 50549; NRS 097; RD 140; UNE 217002; OVE-Richtlinie R25; G99; VDE-AR-N 4105 | |||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
S6-EH3P(7-9)K02-LV-YD-L
7 – 9 kWThree-phaseIP66
View details
SUN-7-12K-SG06LP1-EU-BM3
7 – 12 kWSingle-phaseIP65
View details
SUN-7-12K-SG06LP1-EU-CM3
7 – 12 kWSingle-phaseIP65
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.