100kW-2.5MW C&I ESS (AC-DC) C&I storage system

100kW-2.5MW C&I ESS (AC-DC)

C&I storage system · 257.23 kWh

257.23 kWh100 – 125 kW819.2 V
Price on request
257.23 kWhEnergy capacity
819.2 VNominal voltage
≥6000 cyclesCycle life
100 – 125 kWRated power

Technical data

SUN-100K-PCS01HP3SUN-125K-PCS01HP3SUN-100K-PCS02HP3SUN-125K-PCS02HP3
PV input
MPPT module modelsSUN-MPPT-L01-EU-AM8 / SUN-MPPT-L01-EU-AM8-P / SUN-MPPT-L01-EU-AM10
Max. PV input voltage (V)800
Start-up voltage (V)200
MPPT voltage range (V)180 – 750
MPPT module: Full-load MPPT voltage range (V)450 – 750
Rated PV input voltage (V)600
MPPT module: Max. PV access power (AM8 / AM8-P / AM10) (kW)200 / 250 / 250
MPPT module: Max. PV input power (AM8 / AM8-P / AM10) (kW)160 / 200 / 200
MPPT module: Number of MPPT trackers (AM8 / AM8-P / AM10)8 / 8 / 10
MPPT module: Max. operating PV input current per tracker (AM8 / AM8-P / AM10) (A)40 / 48 / 40
MPPT module: Max. short-circuit current per tracker (AM8 / AM8-P / AM10) (A)60 / 72 / 60
MPPT module: DC output voltage range (V)630 – 1000
MPPT module: Max. DC output current (AM8 / AM8-P / AM10) (A)200 / 250 / 250
PCS DC input voltage range (V)630 – 1000
PCS max. DC input current (A)200200250250
AC output
Rated output power (W)100000125000100000125000
Max. apparent power (VA)110000125000110000125000
Rated AC voltage (V)400
Rated AC output current (A)145181.2145181.2
PhaseThree-phase
Rated AC frequency (Hz)50/60
Max. AC output current (A)159.5181.2159.5181.2
Total harmonic distortion (THDi) (%)<3
Power factor-1 to +1 (adjustable)
Peak (surge) power (W)200000250000200000250000
Rated grid voltage options and range220/380 V; 230/400 V; range 0.85 Un-1.1 Un
Grid connection type3L+N+PE
Rated grid frequency and range50 Hz (45-55 Hz); 60 Hz (55-65 Hz)
DC injection current<0.5% In
On/off-grid switching time (ms)0
Max. parallel units20
Battery
Battery typeLithium-ion
Battery voltage range (V)630 – 1000
Max. charge current (A)175200175200
Max. discharge current (A)175200175200
Charging strategy for Li-ion batterySelf-adaption to BMS
Number of battery inputs1
Battery system modelBOS-B Pro-A3
Cell typeLiFePO4
Usable energy capacity (Wh)231510
Nominal voltage (V)819.2
Nominal capacity (Ah)314
Cycle life (cycles)≥6000
Depth of discharge (DoD) (%)90
BMSIndependent BMS (CAN communication)
Battery module modelBOS-B-Pack16-A3
Battery module nominal energy (kWh)16.08
Battery module nominal voltage (V)51.2
Battery module weight (approx.) (kg)126
Battery module dimensions (W x H x D) (mm)526 × 274.2 × 795.9
Battery modules in series per cluster (optional)5 – 16
Matching mode: PCS only14-16 modules for PCS on-grid applications; 15-16 modules for PCS off-grid applications
Matching mode: PCS + MPPT16 modules (on/off-grid) for MPPT open-circuit voltage <=800 V; 15 modules (on/off-grid) for MPPT open-circuit voltage <=750 V; 14 modules (on-grid) for MPPT open-circuit voltage <=700 V
Battery cluster max. charge/discharge current (A)180
Max. battery clusters per PCS16
Battery operating temperatureCharge 0-55 °C; discharge -20-55 °C
Battery storage temperature (°C)0 – 35
Battery high-voltage control box (PDU) modelBOS-B-PDU-2-A
Battery high-voltage control box operating voltage (V)200 – 1000
Battery high-voltage control box nominal charge/discharge current (A)180
Battery high-voltage control box dimensions (W x H x D) (mm)526 × 167.2 × 788.6
Battery high-voltage control box weight (kg)32
Efficiency
Max. efficiency (%)98.5
European efficiency (%)97.8
MPPT efficiency (%)>99.9
MPPT module: Max. efficiency (%)>99
AC/DC module: Efficiency (full load / peak) (%)>96 / >97
Protection
Protection functionsAC output overcurrent protection; AC output overvoltage protection; AC output short-circuit protection; Thermal protection; Anti-islanding protection; Insulation impedance detection; Residual current detection; Surge protection Type II (DC); Surge protection Type II (AC)
MPPT module protectionsDC input reverse protection; DC switch; Surge protection Type II; DC arc protection (optional); Anti-PID (optional)
General data
Dimensions (W x H x D) (mm)543 × 310 × 775
Weight (kg)81.86
Ingress protection (IP rating)IP65
Operating temperature range (°C)−40 – 60
Relative humidity (%)0 – 95
Max. operating altitude (m)4000
CoolingIntelligent air cooling
Noise level (dB)<75
TopologyNon-isolated
InstallationRack mounted
Warranty (years)5 – 10
Over-voltage categoryOVC II (DC); OVC III (AC)
Battery system: Dimensions (W x H x D) (mm)2150 × 1305 × 800
Battery system: Weight (approx.) (kg)2240
Battery system: Enclosure protection (IP)IP20
Battery system: Relative humidity (%)5 – 85
Battery system: Max. altitude (m)3000
Battery system: Thermal managementSmart fan cooling
Battery system: Warranty (years)10
Communication
DisplayLCD
Communication interfacesWi-Fi; RS485; CAN; Meter
MonitoringLocal touchscreen control; remote monitoring via cloud platform
Battery system: Communication portsTCP; RS485; CAN
Battery system: DisplayLCD showing SOC and fault code
Battery system: Status indicatorYellow: battery high voltage power on; red: battery system alarm
Certifications
Certifications and standardsIEC/EN 62477-1; IEC/EN 62109-1; CE; IEC 62619; IEC 62040; UN38.3
Grid codesIEC 61727; IEC 62116; CEI 0-21; EN 50549; NRS 097; RD 140; UNE 217002; OVE-Richtlinie R25; G99; VDE-AR-N 4105
System
System rated power (kW)100 – 2500
System energy capacity (kWh)257.23
EMSIntegrated EMS: zero-export, TOU optimization, peak shaving, demand management
Fire protectionIntegrated aerosol fire suppression
Max. continuous backup duration (h)32
PV coupling optionsDC coupling (MPPT module); AC coupling (PV inverter)
MPPT module: Over-voltage categoryOVC II
MPPT module: Ingress protectionIP65
MPPT module: CoolingIntelligent air cooling
MPPT module: Dimensions (W x H x D) (AM8 / AM8-P / AM10) (mm)543 x 198 x 700 / 543 x 198 x 700 / 543 x 198 x 720
MPPT module: Weight (AM8 / AM8-P / AM10) (kg)41.75 / 41.75 / 50.6
MPPT module: CommunicationCAN; RS485
AC/DC module modelSUN-80K-CG01-C
AC/DC module: Rated output power (kW)80
AC/DC module: AC input voltage range (V)260 – 530
AC/DC module: Max. AC input current (A)160
AC/DC module: AC frequency range (Hz)45 – 65
AC/DC module: Power factor≥0.99
AC/DC module: THD (%)<5
AC/DC module: DC output voltage range (V)50 – 1000
AC/DC module: Constant-power DC output voltage range (V)300 – 1000
AC/DC module: DC output current (A)0 – 266
AC/DC module: Output current limiting0.3-266 A, continuously adjustable
AC/DC module: Current sharingImbalance < ±5%
AC/DC module: Voltage regulation accuracy< ±0.5%
AC/DC module: Current regulation accuracy<= ±1% (within 20%-100% rated output load)
AC/DC module: Operating temperature (°C)−40 – 75
AC/DC module: Relative humidity (%)≤95
AC/DC module: Max. altitude (m)2000
AC/DC module: CoolingForced air cooling
AC/DC module: Dimensions (W x H x D) (mm)543 × 127 × 740
AC/DC module: Weight (kg)42.2

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

User manuals

  • 100kW-2.5MW C&I ESS (AC-DC) user manual (English)PDF · 4.9 MBDownload

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote