WIT+AXE System C&I storage system

WIT+AXE System

C&I storage system · 50 kWh

50 kWh29.9 – 50 kW512 V
Price on request
50 kWhEnergy capacity
512 VNominal voltage
29.9 – 50 kWRated power
IP66Protection class

Technical data

WIT 29.9K-XHUWIT 30K-XHUWIT 36K-XHUWIT 40K-XHUWIT 50K-XHU
PV input
Max. PV input power (W)59800600007200080000100000
Start-up voltage (V)195
Max. PV input voltage (V)1100
Rated PV input voltage (V)620
MPPT voltage range (V)180 – 1000
Full-load DC voltage range (V)375 – 850375 – 850450 – 850500 – 850620 – 850
Max. input current per MPPT (A)40
Max. short-circuit current per MPPT (A)50
PV strings per MPPT2
Number of MPPT trackers4
AC output
Rated output power (W)2990030000360004000050000
Max. apparent power (VA)2990033000396004400055000
Rated AC voltage (V)400
PhaseThree-phase
Rated AC frequency (Hz)50/60
Max. AC output current (A)45.3506066.783.3
Power factor>0.99 (at nominal power); adjustable -1 to +1
Total harmonic distortion (THDi) (%)<3
Backup output power (W)2990030000360004000050000
Peak (surge) power (W)4485045000540006000075000
Max. parallel units10
Nominal AC voltage options and range380/400 V, -15% to +10%
AC grid connection type3P3W+PE / 3P4W+PE
Nominal AC grid frequency range (Hz)45-55 / 55-65
Max. input current (GEN / AC coupling) (A)90.6 / 45.3100 / 45.5120 / 54.5133.3 / 60.7166.7 / 75.7
Max. output current (smart load) (A)200
Backup: Max. AC apparent power (kVA)29.945546075
Backup: Nominal AC voltage220/230 V (L-N); 380/400 V (L-L)
Backup: Nominal AC frequency (Hz)50/60
Backup: Max. output current (A)68.068.281.891113.6
Backup: Overload capability1.5 x rated power, 10 s
Backup: THDv (linear full load) (%)<3
Battery
Battery voltage range (V)200 – 900
Number of battery inputs3
Max. charging / discharging current per battery input (A)55
BMS communicationRS485; CAN
Battery system modelsAXE 50.0H-1HT-S1 / AXE 60.0H-1HT-S1
Battery typeLithium-ion
System energy capacity (kWh)50 – 60
Usable energy capacity (Wh)45000 – 54000
Nominal voltage (V)512 – 614.4
Battery system operating voltage range (AXE 50.0H / AXE 60.0H) (V)464-568 / 556.8-681.6
Battery system: Max. charge/discharge current (A)100
Max. discharge power (W)50000 – 60000
Max. expandable energy (Wh)180000
Battery modules in series (AXE 50.0H / AXE 60.0H)10 / 12
Battery module modelAXE 5.0H-E1 EU
Battery module nominal energy (kWh)5
Battery module nominal voltage (V)51.2
Battery module operating voltage range (V)46.4 – 56.8
Battery module dimensions (W x H x D) (mm)482 × 131 × 580
Battery module weight (kg)≤47
Efficiency
Max. efficiency (%)98.1
Protection
Protection functionsDC reverse polarity protection; Battery reverse protection; Insulation resistance monitoring; AC/DC surge protection (Type II); AC short-circuit protection; Ground fault monitoring; Grid monitoring; String monitoring; Anti-islanding protection; Residual-current monitoring unit
General data
Dimensions (W x H x D) (mm)920 × 585 × 320
Weight (kg)92
Ingress protection (IP rating)IP66
Operating temperature range (°C)−30 – 60
Relative humidity (%)0 – 95
Max. operating altitude (m)4000
CoolingSmart air cooling
Noise level (dB)≤55
TopologyTransformerless
Warranty (years)5 – 10
Battery system: Installation styleFloor stand
Battery system: Dimensions (W x H x D) (mm)800 × 2000 × 1000
Battery system: Weight (AXE 50.0H / AXE 60.0H) (kg)<=900 / <=1000
Battery system: Ingress protectionIP55
Battery system: Operating temperature (°C)−25 – 55
Battery system: Relative humidity (%)5 – 95
Battery system: CoolingAir cooling
Battery system: Noise (dB)<65
Battery system: Max. altitude (m)2000
Battery system: Warranty (years)10
Communication
DisplayOLED + LED; APP
Communication interfacesRS485; USB; CAN; Wi-Fi (optional); LAN (optional)
Control module communication portCAN; RS485; USB
Monitoring parametersSOC, system voltage, current, cell voltage, cell temperature, PCBA temperature
Certifications
Certifications and standardsIEC/EN 61000-6-1; IEC/EN 61000-6-3; IEC/EN 62109-1; IEC/EN 62109-2; UN 38.3; IEC 62619; IEC 60730; IEC 62477; CE; RoHS; UKCA
Grid codesNRS 097-2-1:2017; EN 50549-1; IEC 62116; IEC 61727; G99:2020; VDE 4105
System
Compatible battery system options per inverterAXE 50.0H-1HT-S1 x1 (51.2 kWh); AXE 55.0H-1HT-S1 x1 (56.32 kWh); AXE 60.0H-1HT-S1 x1 (61.44 kWh); AXE 50.0-60.0H-1HT-S1 x2 (61.44-122.88 kWh); AXE 50.0-60.0H-1HT-S1 x3 (92.16-184.32 kWh)
Control module modelAXE 1000100-C1
Number of control modules1
Control module dimensions (W x H x D) (mm)482 × 131 × 580
Control module weight (kg)≤15
Control module operating voltage range (V)120 – 1000
Control module max. current (A)100

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote