AXE LV Battery
5 – 50 kWh51.2 VIP20
View details
SPH-SPA 3000-6000TL-HUB-AUB
Stackable battery · 5 kWh
5 kWh51.2 VIP66
Price on request
5 kWhEnergy capacity
51.2 VNominal voltage
3 – 6 kWRated power
IP66Protection class
Technical data
| SPH 3000TL-HUB | SPH 3600TL-HUB | SPH 4000TL-HUB | SPH 4600TL-HUB | SPH 5000TL-HUB | SPH 5500TL-HUB | SPH 6000TL-HUB | SPA 3000TL-AUB | SPA 3600TL-AUB | SPA 4000TL-AUB | SPA 4600TL-AUB | SPA 5000TL-AUB | SPA 5500TL-AUB | SPA 6000TL-AUB | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PV input | ||||||||||||||
| Max. PV input power (W) | 6000 | 7200 | 8000 | 9200 | 10000 | 11000 | 12000 | – | – | – | – | – | – | – |
| Max. PV input voltage (V) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | – | – | – | – | – | – | – |
| Rated PV input voltage (V) | 370 | 370 | 370 | 370 | 370 | 370 | 370 | – | – | – | – | – | – | – |
| MPPT voltage range (V) | 100 – 560 | 100 – 560 | 100 – 560 | 100 – 560 | 100 – 560 | 100 – 560 | 100 – 560 | – | – | – | – | – | – | – |
| Start-up voltage (V) | 100 | 100 | 100 | 100 | 100 | 100 | 100 | – | – | – | – | – | – | – |
| Max. input current per MPPT (A) | 16 | 16 | 16 | 16 | 16 | 16 | 16 | – | – | – | – | – | – | – |
| Max. short-circuit current per MPPT (A) | 24 | 24 | 24 | 24 | 24 | 24 | 24 | – | – | – | – | – | – | – |
| Number of MPPT trackers | 2 | 2 | 2 | 2 | 2 | 2 | 2 | – | – | – | – | – | – | – |
| PV strings per MPPT | 1 | 1 | 1 | 1 | 1 | 1 | 1 | – | – | – | – | – | – | – |
| AC output | ||||||||||||||
| Rated output power (W) | 3000 | 3680 | 4000 | 4600 | 5000 | 5500 | 6000 | 3000 | 3680 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Max. apparent power (VA) | 3000 | 3680 | 4000 | 4600 | 5000 | 5500 | 6000 | 3000 | 3680 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Rated AC voltage (V) | 230 | |||||||||||||
| Rated AC output current (A) | 13 | 16 | 17.3 | 20 | 21.7 | 23.9 | 26 | 13 | 16 | 17.3 | 20 | 21.7 | 23.9 | 26 |
| Max. AC output current (A) | 16 | 16 | 22 | 22 | 27 | 25 | 27 | 16 | 16 | 22 | 22 | 27 | 25 | 27 |
| Phase | Single-phase | |||||||||||||
| Rated AC frequency (Hz) | 50/60 | |||||||||||||
| Total harmonic distortion (THDi) (%) | <3 | |||||||||||||
| Power factor | 0.8 leading to 0.8 lagging (adjustable) | |||||||||||||
| Backup rated output apparent power (VA) | 3000 | 3680 | 4000 | 4600 | 5000 | 5500 | 6000 | 3000 | 3680 | 4000 | 4600 | 5000 | 5500 | 6000 |
| Backup nominal voltage (V) | 230 | |||||||||||||
| Backup nominal frequency (Hz) | 50/60 | |||||||||||||
| Backup rated output current (A) | 13 | 16 | 17.3 | 20 | 21.7 | 23.9 | 26 | 13 | 16 | 17.3 | 20 | 21.7 | 23.9 | 26 |
| Backup output THDv (%) | 3 | |||||||||||||
| Backup switch time (ms) | ≤15 | |||||||||||||
| Battery | ||||||||||||||
| Battery type | LiFePO4 | |||||||||||||
| Nominal voltage (V) | 51.2 | |||||||||||||
| Nominal energy capacity (Wh) | 5000 | |||||||||||||
| Max. expandable energy (Wh) | 40000 | |||||||||||||
| Depth of discharge (DoD) (%) | 92 | |||||||||||||
| Battery module model | ALP 5.0L-E1 | |||||||||||||
| Max. discharge/charge rate (C) | 0.75 | |||||||||||||
| Battery module dimensions (W x H x D) (mm) | 690 × 295 × 185 | |||||||||||||
| Max. inverter discharge power with one battery module (W) | 3800 | |||||||||||||
| Efficiency | ||||||||||||||
| Max. efficiency (%) | 97.2 | 97.2 | 97.3 | 97.4 | 97.5 | 97.6 | 97.6 | 97.2 | 97.2 | 97.3 | 97.4 | 97.5 | 97.6 | 97.6 |
| MPPT efficiency (%) | ≥99.5 | |||||||||||||
| Protection | ||||||||||||||
| Protection functions | DC surge protection Type II; AC surge protection Type III | DC surge protection Type II; AC surge protection Type III | DC surge protection Type II; AC surge protection Type III | DC surge protection Type II; AC surge protection Type III | DC surge protection Type II; AC surge protection Type III | DC surge protection Type II; AC surge protection Type III | DC surge protection Type II; AC surge protection Type III | AC surge protection Type III | AC surge protection Type III | AC surge protection Type III | AC surge protection Type III | AC surge protection Type III | AC surge protection Type III | AC surge protection Type III |
| General data | ||||||||||||||
| Operating temperature range (°C) | 0 – 45 | |||||||||||||
| Relative humidity (%) | 5 – 95 | |||||||||||||
| Max. operating altitude (m) | 3000 | |||||||||||||
| Ingress protection (IP rating) | IP66 | |||||||||||||
| Cooling | Natural | |||||||||||||
| Installation | Floor/Wall mount | |||||||||||||
| Warranty (years) | 10 | |||||||||||||
| Self-consumption (W) | <10 | |||||||||||||
| PV connection | MC4 | MC4 | MC4 | MC4 | MC4 | MC4 | MC4 | – | – | – | – | – | – | – |
| AC connection type | Connector | |||||||||||||
| Battery connection | Quick terminal | |||||||||||||
| Communication | ||||||||||||||
| Display | LCD | |||||||||||||
| Communication interfaces | RS485; USB; CAN; Wi-Fi; GPRS | |||||||||||||
| Certifications | ||||||||||||||
| Certifications and standards | CE; IEC 62109; IEC 61000; AS4777.2:2020; CEC | |||||||||||||
| System | ||||||||||||||
| System energy capacity (kWh) | 5 – 40 | |||||||||||||
| Number of inverter modules per system | 1 | |||||||||||||
| Number of battery modules per system | 1 – 8 | |||||||||||||
| System weight for 1 to 8 battery modules (kg) | 80; 125; 170; 215; 260; 305; 350; 395 | |||||||||||||
| System dimensions (W x H x D) for 1 to 8 battery modules (two stacks for 5 to 8 modules) (mm) | 690 x 1102 x 186; 690 x 1397 x 186; 690 x 1692 x 186; 690 x 1987 x 186; 690 x 1692 x 186 + 690 x 705 x 186; 690 x 1692 x 186 + 690 x 1000 x 186; 690 x 1692 x 186 + 690 x 1295 x 186; 690 x 1987 x 186 + 690 x 1295 x 186 | |||||||||||||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
AXE LV Battery
5 – 50 kWh51.2 VIP20
View details
Future-H Series
5.12 kWh51.2 V>4000 cycles
View details
Future-V Series
5.12 kWh51.2 V>4500 cycles
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.