SUN-7.6-12K-SG02LP2-US-AM2-AM3-P
7.6 – 12 kWSplit-phaseIP65
View details
G6-EH3P(8-18)K02-NV-YD-L
Hybrid inverter · Three-phase · 8 – 18 kW
8 – 18 kWThree-phaseIP66
Price on request
8 – 18 kWRated power
Three-phasePhase
2MPPT trackers
97.5 %Max. efficiency
Technical data
| G6-EH3P8K02-NV-YD-L | G6-EH3P10K02-NV-YD-L | G6-EH3P12K02-NV-YD-L | G6-EH3P15K02-NV-YD-L | G6-EH3P18K02-NV-YD-L | |
|---|---|---|---|---|---|
| PV input | |||||
| Max. PV input power (W) | 16000 | 20000 | 24000 | 30000 | 36000 |
| Max. usable PV input power (W) | 12800 | 16000 | 19200 | 24000 | 28800 |
| Max. PV input voltage (V) | 1000 | ||||
| Rated PV input voltage (V) | 550 | ||||
| MPPT voltage range (V) | 200 – 850 | ||||
| Start-up voltage (V) | 160 | ||||
| Max. input current per MPPT (A) | 40 | 40 | 40 | 40 | 42 |
| Max. short-circuit current per MPPT (A) | 50 | ||||
| Number of MPPT trackers | 2 | ||||
| Max. number of PV input strings | 3 | 3 | 3 | 4 | 4 |
| Max. input current per string (A) | 20 | 20 | 20 | 20 | 21 |
| AC output | |||||
| Rated output power (W) | 8000 | 10000 | 12000 | 15000 | 18000 |
| Max. apparent power (VA) | 8000 | 10000 | 12000 | 15000 | 18000 |
| Rated AC voltage (V) | 380 | ||||
| Rated AC output current (A) | 12.2 | 15.2 | 18.2 | 22.8 | 27.3 |
| Phase | Three-phase | ||||
| Rated AC frequency (Hz) | 50 | ||||
| Total harmonic distortion (THDi) (%) | <3 | ||||
| Power factor | >0.99 (0.8 leading to 0.8 lagging) | ||||
| Max. AC input power (grid side) (W) | 12000 | 15000 | 18000 | 22500 | 27000 |
| AC input voltage range (grid side) (V) | 323 – 437 | ||||
| Max. AC input current (grid side) (A) | 18.3 | 22.8 | 27.3 | 34.2 | 41 |
| Backup output power (W) | 8000 | 10000 | 12000 | 15000 | 18000 |
| Peak (surge) power (W) | 16000 | 20000 | 24000 | 30000 | 36000 |
| Off-grid overload duration (s) | 10 | ||||
| Grid / off-grid switchover time (ms) | <10 | ||||
| Rated output voltage, off-grid side | 3/N/PE, 220 V / 380 V | ||||
| Rated frequency, off-grid side (Hz) | 50 | ||||
| Rated output current, off-grid side (A) | 12.2 | 15.2 | 18.2 | 22.8 | 27.3 |
| Max. bypass current (A) | 50 | ||||
| Total voltage harmonic distortion (THDv), off-grid side (%) | <3 | ||||
| Generator input | Yes | ||||
| Max. input power, generator side (W) | 8000 | 10000 | 12000 | 15000 | 18000 |
| Rated input current, generator side (A) | 12.2 | 15.2 | 18.2 | 22.8 | 27.3 |
| Rated input voltage, generator side | 3/N/PE, 220 V / 380 V | ||||
| Rated input frequency, generator side (Hz) | 50 | ||||
| Max. parallel units | 6 | ||||
| Battery | |||||
| Battery type | Lithium or lead-acid | ||||
| Battery voltage range (V) | 40 – 60 | ||||
| Max. charge current (A) | 180 | 220 | 250 | 290 | 320 |
| Max. discharge current (A) | 180 | 220 | 250 | 290 | 320 |
| Number of battery ports / BMS ports | 2 / 1 | ||||
| Max. charge / discharge current per battery port (A) | 175 | ||||
| Battery communication | CAN / RS485 | ||||
| Efficiency | |||||
| Max. efficiency (%) | 97.5 | ||||
| European efficiency (%) | 95 | ||||
| Battery charging efficiency (%) | 95.0 / 94.4 | ||||
| Battery discharging efficiency (%) | 94.5 | ||||
| Protection | |||||
| Protection functions | Surge protection (DC Type II / AC Type II optional); AC output overcurrent protection; insulation resistance protection; residual current (RCD) detection; integrated PV switch; DC reverse polarity protection; DC arc fault protection (optional); anti-islanding protection | ||||
| Protection class / overvoltage category | Class I / OVC II (PV and battery ports), OVC III (grid, off-grid and generator ports) | ||||
| General data | |||||
| Dimensions (W x H x D) (mm) | 430 × 660 × 305 | ||||
| Weight (kg) | 42 | ||||
| Topology | Non-isolated (PV), isolated (battery) | ||||
| Night-time power consumption (W) | <30 | ||||
| Operating temperature range (°C) | −25 – 60 | ||||
| Relative humidity (%) | 0 – 100 | ||||
| Ingress protection (IP rating) | IP66 | ||||
| Noise level (dB) | <65 | ||||
| Cooling | Intelligent redundant air cooling | ||||
| Max. operating altitude (m) | 4000 | ||||
| Max. single-phase load capacity (unbalanced output, % of rated power) (%) | 50 | 50 | 50 | 50 | 40 |
| PV connector | MC4 quick-connect plug | ||||
| Battery connector | Screw terminal | ||||
| AC connector | Screw terminal | ||||
| Communication | |||||
| Display | 7-inch LCD, Bluetooth + app | ||||
| Communication interfaces | Wi-Fi; LAN; Bluetooth; CAN-BMS; CAN-Parallel x 2; RS485-Meter; RS485; DRM; DI; DO x 4; optional 2G/3G/4G | ||||
| Monitoring | Integrated cloud platform with remote control, AI strategy and instant troubleshooting | ||||
| Certifications | |||||
| Certifications and standards | NB/T 10186; NB/T 32004 | ||||
| Grid codes | NB/T 10186; NB/T 32004 | ||||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
SUN-7.6-12K-SG02LP2-US-AM2-AM3-P
7.6 – 12 kWSplit-phaseIP65
View details
SPE 8000-12000 ES
8 – 12 kWSingle-phaseIP20
View details
SUN-8-15K-SG01HP2-US-AM2
8 – 15 kWSplit-phaseIP65
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.