S5-EH1P(3-6)K-L(Smart)
3 – 6 kWSingle-phaseIP65
View details
S6-EH1P(3-10)K-L-PLUS
Hybrid inverter · Single-phase · 3 – 10 kW
3 – 10 kWSingle-phaseIP66
Price on request
3 – 10 kWRated power
Single-phasePhase
2MPPT trackers
96.2 %Max. efficiency
Technical data
| S6-EH1P3K-L-PLUS | S6-EH1P3.6K-L-PLUS | S6-EH1P4.6K-L-PLUS | S6-EH1P5K-L-PLUS | S6-EH1P6K-L-PLUS | S6-EH1P8K-L-PLUS | S6-EH1P9K-L-PLUS(21A) | S6-EH1P10K-L-PLUS(21A) | |
|---|---|---|---|---|---|---|---|---|
| PV input | ||||||||
| Max. PV input power (W) | 6000 | 7200 | 9200 | 10000 | 12000 | 16000 | 18000 | 20000 |
| Max. usable PV input power (W) | 4800 | 5760 | 7360 | 8000 | 9600 | 12800 | 14400 | 16000 |
| Max. PV input voltage (V) | 500 | |||||||
| Rated PV input voltage (V) | 330 | |||||||
| Start-up voltage (V) | 90 | |||||||
| MPPT voltage range (V) | 90 – 435 | |||||||
| Max. input current per MPPT (A) | 16 | 16 | 16 | 16 | 16 | 32 | 42 | 42 |
| Max. input current per input (string) (A) | 16 | 16 | 16 | 16 | 16 | 16 | 21 | 21 |
| Max. short-circuit current per MPPT (A) | 20 | 20 | 20 | 20 | 20 | 40 | 48 | 48 |
| Number of MPPT trackers | 2 | |||||||
| PV strings per MPPT | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
| AC output | ||||||||
| Rated output power (W) | 3000 | 3600 | 4600 | 5000 | 6000 | 8000 | 9000 | 10000 |
| Max. apparent power (VA) | 3000 | 3600 | 4600 | 5000 | 6000 | 8000 | 9000 | 10000 |
| Rated AC voltage (V) | 230 | |||||||
| Nominal AC voltage options (V) | 220 / 230 | |||||||
| Phase | Single-phase | |||||||
| Rated AC frequency (Hz) | 50/60 | |||||||
| Rated AC output current (A) | 13.1 | 15.7 | 20 | 21.8 | 26.1 | 34.8 | 39.1 | 43.5 |
| Power factor | >0.99 (0.8 leading to 0.8 lagging) | |||||||
| Total harmonic distortion (THDi) (%) | <3 | |||||||
| Grid input voltage range (V) | 187 – 253 | |||||||
| Max. grid input current (A) | 21 | 25 | 29 | 32 | 40 | 50 | 60 | 65 |
| Backup output power (W) | 3000 | 3600 | 4600 | 5000 | 6000 | 8000 | 9000 | 10000 |
| Peak (surge) power (W) | 6000 | 7200 | 9200 | 10000 | 12000 | 16000 | 18000 | 20000 |
| Backup overload capability | 2 x rated power for 10 s | |||||||
| On/off-grid switching time (ms) | <10 | |||||||
| Backup rated output voltage (V) | 220 / 230 | |||||||
| Backup rated output frequency (Hz) | 50 / 60 | |||||||
| Backup rated output current (@220 V / @230 V) (A) | 13.7 / 13.1 | 16.4 / 15.7 | 20.9 / 20 | 22.8 / 21.8 | 27.3 / 26.1 | 36.4 / 34.8 | 40.9 / 39.1 | 45.5 / 43.5 |
| Max. bypass current (A) | 35 | 35 | 40 | 40 | 40 | 50 | 60 | 65 |
| Backup output THDv (%) | <2 | |||||||
| Generator input | Yes | |||||||
| Max. generator input power (W) | 3000 | 3600 | 4600 | 5000 | 6000 | 8000 | 9000 | 10000 |
| Generator rated input current (@220 V / @230 V) (A) | 13.7 / 13.1 | 16.4 / 15.7 | 20.9 / 20 | 22.8 / 21.8 | 27.3 / 26.1 | 36.4 / 34.8 | 40.9 / 39.1 | 45.5 / 43.5 |
| Generator rated input voltage (V) | 220 / 230 | |||||||
| Generator rated input frequency (Hz) | 50 / 60 | |||||||
| Max. parallel units | 6 | |||||||
| Battery | ||||||||
| Battery type | Lithium battery / Lead-acid battery | |||||||
| Battery voltage range (V) | 40 – 60 | |||||||
| Max. charge power (W) | 3000 | 3600 | 4600 | 5000 | 6000 | 8000 | 9000 | 10000 |
| Max. discharge power (W) | 3000 | 3600 | 4600 | 5000 | 6000 | 8000 | 9000 | 10000 |
| Max. charge current (A) | 70 | 80 | 105 | 112 | 135 | 190 | 200 | 210 |
| Max. discharge current (A) | 70 | 80 | 105 | 112 | 135 | 190 | 200 | 210 |
| Battery ports / BMS ports | 1 / 1 | |||||||
| Battery communication | CAN / RS485 | |||||||
| Efficiency | ||||||||
| Max. efficiency (%) | 96.2 | |||||||
| European efficiency (%) | 96.1 | |||||||
| Max. PV charging efficiency (%) | 95.3 / 93.9 | |||||||
| Battery discharging efficiency (%) | 93.8 | |||||||
| Protection | ||||||||
| Protection functions | Surge protection; AC output over-current protection; Insulation resistance protection; Residual current detection; Integrated PV switch; DC reverse-polarity protection; DC arc-fault protection (optional); Anti-islanding protection | |||||||
| Protection class / overvoltage category | Class I; overvoltage category II (PV and battery ports), category III (grid, backup and generator ports) | |||||||
| General data | ||||||||
| Dimensions (W x H x D) (mm) | 335 × 560 × 253 | |||||||
| Weight (kg) | 23 | 23 | 23 | 23 | 23 | 23.5 | 23.8 | 23.8 |
| Topology | Non-isolated (PV), isolated (battery) | |||||||
| Self-consumption (W) | <40 | |||||||
| Operating temperature range (°C) | −25 – 60 | |||||||
| Relative humidity (%) | 0 – 100 | |||||||
| Ingress protection (IP rating) | IP66 | |||||||
| Noise level (dB) | <40 | <40 | <40 | <40 | <40 | <65 | <65 | <65 |
| Cooling | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection | Smart fan cooling | Smart fan cooling | Smart fan cooling |
| Max. operating altitude (m) | 3000 | |||||||
| PV port | MC4 connector | |||||||
| Battery port | Terminal block | |||||||
| AC port | Terminal block | |||||||
| Communication | ||||||||
| Display | 7-inch LCD | |||||||
| Communication interfaces | Wi-Fi; LAN; Bluetooth; CAN-BMS; CAN-Parallel x 2; RS485-Meter; RS485; DRM; DI; DO x 2; 2G/3G/4G (optional) | |||||||
| Monitoring | Bluetooth + mobile app | |||||||
| Certifications | ||||||||
| Certifications and standards | IEC/EN 62109-1/-2; EN 61000-6-2/-3 | |||||||
| Grid codes | NRS 097-2-1; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; EN 50549-1; MEA; PEA; NBR 16149; NBR 16150; G98; G99; CEI 0-21; NTS 631 Type A | |||||||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
S5-EH1P(3-6)K-L(Smart)
3 – 6 kWSingle-phaseIP65
View details
S6-EH1P(3-6)K-L-EU
3 – 6 kWSingle-phaseIP66
View details
S6-EH3P(3-12)K-H
3 – 12 kWThree-phaseIP66
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.