G6-EH3P(30-60)K-NV-YD-H
30 – 60 kWThree-phaseIP66
View details
S6-EH3P(30-50)K-H-ND
Hybrid inverter · Three-phase · 30 – 50 kW
30 – 50 kWThree-phaseIP66
Price on request
30 – 50 kWRated power
Three-phasePhase
3 – 4MPPT trackers
97.8 %Max. efficiency
Technical data
| S6-EH3P30K-H-ND | S6-EH3P40K-H-ND | S6-EH3P49K-H-ND | S6-EH3P50K-H-ND | |
|---|---|---|---|---|
| PV input | ||||
| Max. PV input power (W) | 60000 | 80000 | 98000 | 100000 |
| Max. usable PV input power (W) | 60000 | 80000 | 96000 | 96000 |
| Max. PV input voltage (V) | 1000 | |||
| Rated PV input voltage (V) | 600 | |||
| MPPT voltage range (V) | 150 – 850 | |||
| Start-up voltage (V) | 180 | |||
| Max. input current per MPPT (A) | 40 | |||
| Max. short-circuit current per MPPT (A) | 60 | |||
| Number of MPPT trackers | 3 | 4 | 4 | 4 |
| Max. number of PV input strings | 6 | 8 | 8 | 8 |
| Max. input current per string (A) | 20 | |||
| AC output | ||||
| Rated output power (W) | 30000 | 40000 | 49000 | 50000 |
| Max. apparent power (VA) | 30000 | 40000 | 49000 | 50000 |
| Rated AC voltage (V) | 400 | |||
| Rated AC output current (A) | 43.3 | 57.7 | 70.7 | 72.2 |
| Phase | Three-phase | |||
| Rated AC frequency (Hz) | 50/60 | |||
| Max. AC output current (A) | 43.3 | 57.7 | 70.7 | 72.2 |
| Total harmonic distortion (THDi) (%) | <3 | |||
| Power factor | >0.99 (0.8 leading to 0.8 lagging) | |||
| Backup output power (W) | 30000 | 40000 | 49000 | 50000 |
| Peak (surge) power (W) | 48000 | 64000 | 78400 | 80000 |
| Generator input | Yes | |||
| Rated AC voltage options (grid, generator and off-grid side) | 3/N/PE, 220 V / 380 V or 230 V / 400 V | |||
| Rated output current at 380 V / 400 V (grid side) (A) | 45.6 / 43.3 | 60.8 / 57.7 | 74.5 / 70.7 | 76 / 72.2 |
| Max. bypass current (380 V / 400 V) (A) | 91.2 / 86.6 | 121.6 / 115.4 | 149 / 141.4 | 152 / 144.4 |
| Generator input: Max. input power (W) | 30000 | 40000 | 49000 | 50000 |
| Generator input: Rated input current (380 V / 400 V) (A) | 45.6 / 43.3 | 60.8 / 57.7 | 74.5 / 70.7 | 76 / 72.2 |
| Generator input range (% of rated power) (%) | 20 – 100 | |||
| Off-grid: Peak power duration | 2 s | |||
| Off-grid: Rated output current (380 V / 400 V) (A) | 45.6 / 43.3 | 60.8 / 57.7 | 74.5 / 70.7 | 76 / 72.2 |
| Off-grid: Grid / off-grid switchover time | <10 ms | |||
| Off-grid: Total voltage harmonic distortion (THDv) (%) | <2 | |||
| Smart multi-source input port (select one) | Grid-connected PV system; wind system; diesel generator | |||
| PV coupling | DC and AC coupling | |||
| Max. parallel system capacity (kW) | 500 | |||
| Battery | ||||
| Battery type | Lithium-ion | |||
| Battery voltage range (V) | 150 – 800 | |||
| Max. charge current (A) | 140 | |||
| Max. discharge current (A) | 140 | |||
| Max. charge power (W) | 33000 | 44000 | 53900 | 55000 |
| Max. discharge power (W) | 33000 | 44000 | 53900 | 55000 |
| Number of battery input ports | 2 | |||
| Max. charge/discharge current per battery port (A) | 70 | |||
| Max. charge/discharge power per battery port (W) | 33000 | 35000 | 35000 | 35000 |
| Battery communication | CAN / RS485 | |||
| Compatible battery capacity (Ah) | 100 – 280 | |||
| Efficiency | ||||
| Max. efficiency (%) | 97.8 | |||
| European efficiency (%) | 97.4 | |||
| Max. PV charging efficiency (%) | 98.5 | |||
| Max. battery charge/discharge efficiency (%) | 97.5 | |||
| Protection | ||||
| Protection functions | Anti-islanding protection; AC output overcurrent protection; AC short-circuit protection; Integrated DC switch; DC reverse polarity protection; Surge protection (DC Type II / AC Type II); DC arc fault protection (optional) | |||
| General data | ||||
| Dimensions (W x H x D) (mm) | 530 × 880 × 290 | |||
| Weight (kg) | 73 | |||
| Ingress protection (IP rating) | IP66 | |||
| Operating temperature range (°C) | −25 – 60 | |||
| Relative humidity (%) | 0 – 100 | |||
| Max. operating altitude (m) | 4000 | |||
| Cooling | Smart air cooling | |||
| Topology | Transformerless | |||
| Night-time power consumption (W) | <35 | |||
| PV connector | MC4 quick connector | |||
| Battery connector | Wiring terminal | |||
| AC connector | Terminal block | |||
| Communication | ||||
| Display | LED indicators; Bluetooth + app | |||
| Communication interfaces | CAN; RS485; Ethernet; Wi-Fi (optional); Cellular (optional); LAN (optional) | |||
| Monitoring | Integrated cloud platform: remote control, AI strategies, instant fault troubleshooting | |||
| Certifications | ||||
| Certifications and standards | IEC/EN 62109-1; IEC/EN 62109-2; IEC/EN 61000-6-2; IEC/EN 61000-6-4; EN 55011 | |||
| Grid codes | G99; VDE-AR-N 4105; VDE V 0124; EN 50549-1; EN 50549-10; VDE 0126; UTE C 15; VFR:2019; NTS 631; RD 1699; RD 244; UNE 206006; UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS 2018.2; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA; PORTARIA No. 140 of 21 March 2022 | |||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
G6-EH3P(30-60)K-NV-YD-H
30 – 60 kWThree-phaseIP66
View details
WIT 50-100K-HU-AU
50 – 100 kWThree-phaseIP66
View details
WIT 50-150K-XHU-US
50 – 150 kWThree-phaseIP66
View details
Request a quotation