S6-EH3P(80-125)K10-NV-YD-H Hybrid inverter

S6-EH3P(80-125)K10-NV-YD-H

Hybrid inverter · Three-phase · 80 – 125 kW

80 – 125 kWThree-phaseIP66
Price on request
80 – 125 kWRated power
Three-phasePhase
10MPPT trackers
97.5 %Max. efficiency

Technical data

S6-EH3P80K10-NV-YD-HS6-EH3P100K10-NV-YD-HS6-EH3P125K10-NV-YD-H
PV input
Max. PV input power (W)160000200000250000
Max. usable PV input power (W)160000200000250000
Max. PV input voltage (V)1000
Rated PV input voltage (V)600
MPPT voltage range (V)150 – 950
Start-up voltage (V)180
Max. input current per MPPT (A)42
Max. short-circuit current per MPPT (A)60
Number of MPPT trackers10
PV strings per MPPT2
Max. number of PV input strings20
Max. input current per string (A)21
AC output
Rated output power (W)80000100000125000
Max. apparent power (VA)80000100000125000
Rated AC voltage (V)400
Rated AC output current (A)115.5144.3180.4
Rated AC output current at 380 V (grid side) (A)121.6151.9189.9
PhaseThree-phase
Rated AC frequency (Hz)50/60
Total harmonic distortion (THDi) (%)<3
Power factor>0.99 (0.8 leading to 0.8 lagging)
Rated grid voltage options3/N/PE, 220 V / 380 V, 230 V / 400 V
Max. AC input power (grid side), 380 V / 400 V (W)160000164500 / 173200164500 / 173200
AC input voltage range (grid side) (V)304 – 460
Max. AC input current (grid side) (A)250
Backup output power (W)80000100000125000
Peak (surge) power (W)160000200000200000
Off-grid overload capability (critical loads)2 x rated power for 200 ms; 1.6 x rated power for 10 s2 x rated power for 200 ms; 1.6 x rated power for 10 s1.6 x rated power for 200 ms; 1.4 x rated power for 10 s
Grid / off-grid switchover time (single unit) (ms)<10
Grid / off-grid switchover time (parallel system, up to 6 units) (ms)<20
Rated output voltage, off-grid side3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated output frequency, off-grid side (Hz)50/60
Rated output current, off-grid side (380 V / 400 V) (A)121.6 / 115.5151.9 / 144.3189.9 / 180.4
Max. bypass current (380 V / 400 V) (A)121.6 / 115.5151.9 / 144.3189.9 / 180.4
Total voltage harmonic distortion (THDv), off-grid side (%)<3
Generator inputYes
Max. input power, generator side (W)80000100000125000
Rated input current, generator side (380 V / 400 V) (A)121.6 / 115.5151.9 / 144.3189.9 / 180.4
Rated input voltage, generator side3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated input frequency, generator side (Hz)50/60
Max. parallel system capacity (kW)1250
Battery
Battery typeLithium-ion
Battery voltage range (V)300 – 950
Max. charge current (A)200
Max. discharge current (A)200
Number of battery ports / BMS ports2
Max. charge / discharge current per battery port (A)100
Battery communicationCAN
Compatible battery module capacity (Ah)100 – 314
Efficiency
Max. efficiency (%)97.5
European efficiency (%)96.997.197.2
Battery charging efficiency (%)98.2 / 97.0
Battery discharging efficiency (%)97.0
Protection
Protection functionsSurge protection (DC Type II / AC Type II); AC output overcurrent protection; Insulation resistance protection; Residual current (RCD) detection; Integrated PV switch; DC reverse polarity protection; DC arc fault protection (optional); Anti-islanding protection
Protection class / overvoltage categoryClass I / OVC II (DC), OVC III (AC)
General data
Dimensions (W x H x D) (mm)1174 × 814 × 400
Weight (kg)170
Ingress protection (IP rating)IP66
Operating temperature range (°C)−25 – 60
Relative humidity (%)0 – 100
Max. operating altitude (m)3000
CoolingIntelligent redundant air cooling
TopologyNon-isolated
Night-time power consumption (W)<45
Max. single-phase load capacity (% of rated power) (%)33
PV connectorMC4 quick-connect terminal
Battery connectorThrough-wall terminal
AC connectorTerminal block
Communication
Display7.0-inch display, Bluetooth + app
Communication interfacesWi-Fi + LAN + Bluetooth; CAN-BMS x 2; CAN-Parallel x 2; LAN; RS485-Meter; RS485; DRM; DI x 5; DO x 4; optional 4G
MonitoringIntegrated cloud platform with remote control, AI strategy and instant troubleshooting
Certifications
Certifications and standardsIEC/EN 62109-1/-2; IEC/EN 61000-6-2/-4; EN 55011
Grid codesG99; VDE-AR-N 4105; VDE V 0124; EN 50549-1; EN 50549-2; EN 50549-10; VDE 0126; UTE C 15; VFR:2019; NTS 631; UNE 217001; CEI 0-21; C10/11; NRS 097-2-1; TOR; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA; PORTARIA Nº 140; PORTARIA Nº 515
Note on grid codesPlanned certification standards only; confirm the actual status with the local team before quoting

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote