WIT 63-125K-XHU
63 – 125 kWThree-phaseIP66
View details
S6-EH3P(80-125)K10-NV-YD-H
Hybrid inverter · Three-phase · 80 – 125 kW
80 – 125 kWThree-phaseIP66
Price on request
80 – 125 kWRated power
Three-phasePhase
10MPPT trackers
97.5 %Max. efficiency
Technical data
| S6-EH3P80K10-NV-YD-H | S6-EH3P100K10-NV-YD-H | S6-EH3P125K10-NV-YD-H | |
|---|---|---|---|
| PV input | |||
| Max. PV input power (W) | 160000 | 200000 | 250000 |
| Max. usable PV input power (W) | 160000 | 200000 | 250000 |
| Max. PV input voltage (V) | 1000 | ||
| Rated PV input voltage (V) | 600 | ||
| MPPT voltage range (V) | 150 – 950 | ||
| Start-up voltage (V) | 180 | ||
| Max. input current per MPPT (A) | 42 | ||
| Max. short-circuit current per MPPT (A) | 60 | ||
| Number of MPPT trackers | 10 | ||
| PV strings per MPPT | 2 | ||
| Max. number of PV input strings | 20 | ||
| Max. input current per string (A) | 21 | ||
| AC output | |||
| Rated output power (W) | 80000 | 100000 | 125000 |
| Max. apparent power (VA) | 80000 | 100000 | 125000 |
| Rated AC voltage (V) | 400 | ||
| Rated AC output current (A) | 115.5 | 144.3 | 180.4 |
| Rated AC output current at 380 V (grid side) (A) | 121.6 | 151.9 | 189.9 |
| Phase | Three-phase | ||
| Rated AC frequency (Hz) | 50/60 | ||
| Total harmonic distortion (THDi) (%) | <3 | ||
| Power factor | >0.99 (0.8 leading to 0.8 lagging) | ||
| Rated grid voltage options | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||
| Max. AC input power (grid side), 380 V / 400 V (W) | 160000 | 164500 / 173200 | 164500 / 173200 |
| AC input voltage range (grid side) (V) | 304 – 460 | ||
| Max. AC input current (grid side) (A) | 250 | ||
| Backup output power (W) | 80000 | 100000 | 125000 |
| Peak (surge) power (W) | 160000 | 200000 | 200000 |
| Off-grid overload capability (critical loads) | 2 x rated power for 200 ms; 1.6 x rated power for 10 s | 2 x rated power for 200 ms; 1.6 x rated power for 10 s | 1.6 x rated power for 200 ms; 1.4 x rated power for 10 s |
| Grid / off-grid switchover time (single unit) (ms) | <10 | ||
| Grid / off-grid switchover time (parallel system, up to 6 units) (ms) | <20 | ||
| Rated output voltage, off-grid side | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||
| Rated output frequency, off-grid side (Hz) | 50/60 | ||
| Rated output current, off-grid side (380 V / 400 V) (A) | 121.6 / 115.5 | 151.9 / 144.3 | 189.9 / 180.4 |
| Max. bypass current (380 V / 400 V) (A) | 121.6 / 115.5 | 151.9 / 144.3 | 189.9 / 180.4 |
| Total voltage harmonic distortion (THDv), off-grid side (%) | <3 | ||
| Generator input | Yes | ||
| Max. input power, generator side (W) | 80000 | 100000 | 125000 |
| Rated input current, generator side (380 V / 400 V) (A) | 121.6 / 115.5 | 151.9 / 144.3 | 189.9 / 180.4 |
| Rated input voltage, generator side | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||
| Rated input frequency, generator side (Hz) | 50/60 | ||
| Max. parallel system capacity (kW) | 1250 | ||
| Battery | |||
| Battery type | Lithium-ion | ||
| Battery voltage range (V) | 300 – 950 | ||
| Max. charge current (A) | 200 | ||
| Max. discharge current (A) | 200 | ||
| Number of battery ports / BMS ports | 2 | ||
| Max. charge / discharge current per battery port (A) | 100 | ||
| Battery communication | CAN | ||
| Compatible battery module capacity (Ah) | 100 – 314 | ||
| Efficiency | |||
| Max. efficiency (%) | 97.5 | ||
| European efficiency (%) | 96.9 | 97.1 | 97.2 |
| Battery charging efficiency (%) | 98.2 / 97.0 | ||
| Battery discharging efficiency (%) | 97.0 | ||
| Protection | |||
| Protection functions | Surge protection (DC Type II / AC Type II); AC output overcurrent protection; Insulation resistance protection; Residual current (RCD) detection; Integrated PV switch; DC reverse polarity protection; DC arc fault protection (optional); Anti-islanding protection | ||
| Protection class / overvoltage category | Class I / OVC II (DC), OVC III (AC) | ||
| General data | |||
| Dimensions (W x H x D) (mm) | 1174 × 814 × 400 | ||
| Weight (kg) | 170 | ||
| Ingress protection (IP rating) | IP66 | ||
| Operating temperature range (°C) | −25 – 60 | ||
| Relative humidity (%) | 0 – 100 | ||
| Max. operating altitude (m) | 3000 | ||
| Cooling | Intelligent redundant air cooling | ||
| Topology | Non-isolated | ||
| Night-time power consumption (W) | <45 | ||
| Max. single-phase load capacity (% of rated power) (%) | 33 | ||
| PV connector | MC4 quick-connect terminal | ||
| Battery connector | Through-wall terminal | ||
| AC connector | Terminal block | ||
| Communication | |||
| Display | 7.0-inch display, Bluetooth + app | ||
| Communication interfaces | Wi-Fi + LAN + Bluetooth; CAN-BMS x 2; CAN-Parallel x 2; LAN; RS485-Meter; RS485; DRM; DI x 5; DO x 4; optional 4G | ||
| Monitoring | Integrated cloud platform with remote control, AI strategy and instant troubleshooting | ||
| Certifications | |||
| Certifications and standards | IEC/EN 62109-1/-2; IEC/EN 61000-6-2/-4; EN 55011 | ||
| Grid codes | G99; VDE-AR-N 4105; VDE V 0124; EN 50549-1; EN 50549-2; EN 50549-10; VDE 0126; UTE C 15; VFR:2019; NTS 631; UNE 217001; CEI 0-21; C10/11; NRS 097-2-1; TOR; IEC 62116; IEC 61727; IEC 60068; IEC 61683; EN 50530; MEA; PEA; PORTARIA Nº 140; PORTARIA Nº 515 | ||
| Note on grid codes | Planned certification standards only; confirm the actual status with the local team before quoting | ||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
WIT 63-125K-XHU
63 – 125 kWThree-phaseIP66
View details
G6-EH3P(80-125)K10-NV-YD-H
80 – 125 kWThree-phaseIP66
View details
SUN-100-125K-SG02HP3-EU-GM8-GM10
100 – 125 kWThree-phaseIP65
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.