WIT 63-125K-XHU
63 – 125 kWThree-phaseIP66
View details
SUN-100-125K-SG02HP3-EU-GM8-GM10
Hybrid inverter · Three-phase · 100 – 125 kW
100 – 125 kWThree-phaseIP65
Price on request
100 – 125 kWRated power
Three-phasePhase
8 – 10MPPT trackers
98.7 %Max. efficiency
Technical data
| SUN-100K-SG02HP3-EU-GM8 | SUN-100K-SG02HP3-EU-GM10 | SUN-125K-SG02HP3-EU-GM10 | |
|---|---|---|---|
| PV input | |||
| Max. PV input power (W) | 200000 | 200000 | 250000 |
| Max. usable PV input power (W) | 160000 | 160000 | 200000 |
| Max. PV input voltage (V) | 1000 | ||
| Rated PV input voltage (V) | 650 | ||
| MPPT voltage range (V) | 150 – 850 | ||
| Start-up voltage (V) | 180 | ||
| Max. input current per MPPT (A) | 42 | ||
| Max. short-circuit current per MPPT (A) | 63 | ||
| Number of MPPT trackers | 8 | 10 | 10 |
| PV strings per MPPT | 2 | ||
| AC output | |||
| Rated output power (W) | 100000 | 100000 | 125000 |
| Max. apparent power (VA) | 110000 | 110000 | 135000 |
| Rated AC voltage (V) | 400 | ||
| Rated AC output current (A) | 145 | 145 | 181.2 |
| Max. AC output current (A) | 159.5 | 159.5 | 195.7 |
| Phase | Three-phase | ||
| Rated AC frequency (Hz) | 50/60 | ||
| Total harmonic distortion (THDi) (%) | <3 | ||
| Power factor | 0.8 leading to 0.8 lagging | ||
| Peak (surge) power (W) | 150000 | 150000 | 187500 |
| Peak power duration (off-grid) (s) | 10 | ||
| Generator input | Yes | ||
| Max. parallel units | 10 | ||
| Max. continuous AC pass-through current (grid to load) (A) | 250 | ||
| Rated grid voltage options and range | 220/380 V; 230/400 V; range 0.85 Un-1.1 Un | ||
| Grid connection type | 3L+N+PE | ||
| Rated grid frequency and range | 50 Hz (45-55 Hz); 60 Hz (55-65 Hz) | ||
| DC injection current | <0.5% In | ||
| Battery | |||
| Battery type | Lithium-ion | ||
| Battery voltage range (V) | 160 – 1000 | ||
| Max. charge current (A) | 200 | ||
| Max. discharge current (A) | 200 | ||
| Max. charge / discharge current per battery input (A) | 100 | ||
| Charging strategy for Li-ion battery | Self-adaption to BMS | ||
| Number of battery inputs | 2 | ||
| Efficiency | |||
| Max. efficiency (%) | 98.7 | ||
| European efficiency (%) | 98.1 | ||
| MPPT efficiency (%) | >99 | ||
| Protection | |||
| Protection functions | DC reverse polarity protection; AC output overcurrent protection; Thermal protection; AC output overvoltage protection; AC output short circuit protection; DC component monitoring; Arc fault circuit interrupter (AFCI) (optional); Anti-islanding protection; DC switch; Insulation impedance detection; Residual current detection | ||
| Surge protection level | Type II (DC), Type II (AC) | ||
| General data | |||
| Dimensions (W x H x D) (mm) | 734 × 1091 × 344 | ||
| Weight (kg) | 161.7 | ||
| Ingress protection (IP rating) | IP65 | ||
| Operating temperature range (°C) | −40 – 60 | ||
| Power derating starts above (°C) | 45 | ||
| Relative humidity (%) | 0 – 100 | ||
| Max. operating altitude (m) | 3000 | ||
| Noise level (dB) | ≤65 | ||
| Cooling | Intelligent air cooling | ||
| Topology | Non-isolated | ||
| Warranty (years) | 5 – 10 | ||
| Overvoltage category | OVC II (DC), OVC III (AC) | ||
| Communication | |||
| Display | LCD + LED | ||
| Communication interfaces | RS485; RS232; CAN | ||
| Monitoring | GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional) | ||
| Certifications | |||
| Certifications and standards | IEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2 | ||
| Grid codes | IEC 61727; IEC 62116; CEI 0-21; EN 50549; NRS 097; RD 140; UNE 217002; OVE-Richtlinie R25; G99; VDE-AR-N 4105 | ||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
WIT 63-125K-XHU
63 – 125 kWThree-phaseIP66
View details
G6-EH3P(80-125)K10-NV-YD-H
80 – 125 kWThree-phaseIP66
View details
S6-EH3P(80-125)K10-NV-YD-H
80 – 125 kWThree-phaseIP66
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.