MID 30-50KTL3-X2
33 – 50 kWThree-phaseIP66
View details
SUN-33-50K-G04P3-EU-AM4-LV
String inverter · Three-phase · 33 – 50 kW
33 – 50 kWThree-phaseIP65
Price on request
33 – 50 kWRated power
Three-phasePhase
4MPPT trackers
98.6 – 98.7 %Max. efficiency
Technical data
| SUN-33K-G04P3-EU-AM4-LV | SUN-35K-G04P3-EU-AM4-LV | SUN-40K-G04P3-EU-AM4-LV | SUN-45K-G04P3-EU-AM4-LV | SUN-50K-G04P3-EU-AM4-LV | |
|---|---|---|---|---|---|
| PV input | |||||
| Max. PV input power (W) | 49500 | 52500 | 60000 | 67500 | 75000 |
| Max. PV input voltage (V) | 800 | ||||
| Rated PV input voltage (V) | 500 | ||||
| MPPT voltage range (V) | 200 – 700 | ||||
| Start-up voltage (V) | 250 | ||||
| Max. input current per MPPT (A) | 40 | ||||
| Max. short-circuit current per MPPT (A) | 60 | ||||
| Number of MPPT trackers | 4 | ||||
| PV strings per MPPT | 3 | 3 | 4 | 4 | 4 |
| AC output | |||||
| Rated output power (W) | 33000 | 35000 | 40000 | 45000 | 50000 |
| Max. apparent power (VA) | 33000 | 35000 | 40000 | 45000 | 50000 |
| Rated AC voltage (V) | 230 | ||||
| Rated AC voltage options (phase / line-to-line) (V) | 127/220; 133/230 | ||||
| AC voltage range (relative to rated voltage) | 0.85 Un-1.1 Un | ||||
| Rated AC output current (A) | 82.8 | 87.8 | 100.3 | 112.8 | 125.4 |
| Max. AC output current (A) | 82.8 | 87.8 | 100.3 | 112.8 | 125.4 |
| Phase | Three-phase | ||||
| Grid connection type | 3L/N/PE | ||||
| Rated AC frequency (Hz) | 50/60 | ||||
| Grid frequency range (50 Hz / 60 Hz) (Hz) | 45-55 / 55-65 | ||||
| Power factor | 0.8 leading to 0.8 lagging | ||||
| Total harmonic distortion (THDi) (%) | <3 | ||||
| DC injection current | <0.5% In | ||||
| Efficiency | |||||
| Max. efficiency (%) | 98.6 | 98.6 | 98.7 | 98.7 | 98.7 |
| MPPT efficiency (%) | >99 | ||||
| Protection | |||||
| Protection functions | DC reverse polarity protection; AC output overcurrent protection; AC output overvoltage protection; AC output short-circuit protection; Thermal protection; Insulation impedance detection; DC component monitoring; Arc fault circuit interrupter (AFCI) (optional); Anti-islanding protection; Residual current detection; DC switch | ||||
| Surge protection level | Type II (DC), Type II (AC) | ||||
| Anti-PID function | Optional | ||||
| General data | |||||
| Dimensions (W x H x D) (mm) | 698 × 613 × 236.5 | ||||
| Weight (kg) | 53.7 | ||||
| Ingress protection (IP rating) | IP65 | ||||
| Operating temperature range (°C) | −25 – 65 | ||||
| Power derating above (°C) | 45 | ||||
| Relative humidity (%) | 0 – 100 | ||||
| Max. operating altitude (m) | 4000 | ||||
| Cooling | Intelligent air cooling | ||||
| Noise level (dB) | ≤55 | ||||
| Topology | Non-isolated | ||||
| Overvoltage category | OVC II (DC), OVC III (AC) | ||||
| Warranty (years) | 5 | ||||
| Communication | |||||
| Communication interfaces | RS485; RS232 | ||||
| Monitoring | GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional); string intelligent monitoring (optional) | ||||
| Certifications | |||||
| Certifications and standards | IEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2 | ||||
| Grid codes | NBR 16149; NBR 16150; EN 50549; RD 140 | ||||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
MID 30-50KTL3-X2
33 – 50 kWThree-phaseIP66
View details
MID 36-60KTL3-X3
36 – 60 kWThree-phaseIP66
View details
G6-GC3P40K-NV-ND
40 kWThree-phaseIP66
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.