SUN-60-75K-G01P3-EU-AM8-LV
60 – 75 kWThree-phaseIP65
View details
SUN-60-80K-G04P3-EU-AM4
String inverter · Three-phase · 60 – 80 kW
60 – 80 kWThree-phaseIP65
Price on request
60 – 80 kWRated power
Three-phasePhase
4MPPT trackers
98.6 – 98.7 %Max. efficiency
Technical data
| SUN-60K-G04P3-EU-AM4 | SUN-70K-G04P3-EU-AM4 | SUN-75K-G04P3-EU-AM4 | SUN-80K-G04P3-EU-AM4 | |
|---|---|---|---|---|
| PV input | ||||
| Max. PV input power (W) | 90000 | 105000 | 112500 | 120000 |
| Max. PV input voltage (V) | 1100 | |||
| Start-up voltage (V) | 250 | |||
| MPPT voltage range (V) | 200 – 1000 | |||
| Rated PV input voltage (V) | 600 | 600 | 720 | 720 |
| Max. input current per MPPT (A) | 40 | |||
| Max. short-circuit current per MPPT (A) | 60 | |||
| Number of MPPT trackers | 4 | |||
| PV strings per MPPT | 3 | 4 | 4 | 4 |
| AC output | ||||
| Rated output power (W) | 60000 | 70000 | 75000 | 80000 |
| Max. apparent power (VA) | 66000 | 77000 | 82500 | 88000 |
| Rated AC voltage (V) | 400 | |||
| Rated AC voltage options (V) | 220/380; 230/400 | |||
| AC voltage range | 0.85 Un-1.1 Un | |||
| Phase | Three-phase | |||
| Grid connection form | 3L / N / PE | |||
| Rated AC output current (A) | 87 | 101.5 | 108.7 | 115.9 |
| Rated AC output current at 380 V line voltage (A) | 90.9 | 106.1 | 113.6 | 121.2 |
| Max. AC output current (A) | 95.7 | 111.6 | 119.6 | 127.5 |
| Max. AC output current at 380 V line voltage (A) | 100 | 116.7 | 125 | 133.3 |
| Rated AC frequency (Hz) | 50/60 | |||
| AC grid frequency range (50 Hz / 60 Hz) (Hz) | 45-55 / 55-65 | |||
| Power factor | 0.8 leading to 0.8 lagging (adjustable) | |||
| Total harmonic distortion (THDi) (%) | <3 | |||
| DC injection current | <0.5% In | |||
| Efficiency | ||||
| Max. efficiency (%) | 98.6 | 98.7 | 98.7 | 98.7 |
| European efficiency (%) | 98 | 98.1 | 98.1 | 98.1 |
| MPPT efficiency (%) | >99 | |||
| Protection | ||||
| Protection functions | DC reverse polarity protection; AC output overcurrent protection; AC output overvoltage protection; AC output short-circuit protection; Thermal protection; Insulation impedance detection; DC component monitoring; Arc fault circuit interrupter (AFCI) (optional); Anti-islanding protection; Residual current detection; DC switch | |||
| Surge protection level | Type II (DC), Type II (AC) | |||
| Anti-PID function | Optional | |||
| General data | ||||
| Dimensions (W x H x D) (mm) | 698 × 613 × 236.5 | |||
| Weight (kg) | 53.7 | |||
| Ingress protection (IP rating) | IP65 | |||
| Operating temperature range (°C) | −25 – 60 | |||
| Power derating above (°C) | 45 | |||
| Relative humidity (%) | 0 – 100 | |||
| Max. operating altitude (m) | 4000 | |||
| Noise level (dB) | ≤55 | |||
| Cooling | Intelligent air cooling | |||
| Topology | Non-isolated | |||
| Overvoltage category | OVC II (DC), OVC III (AC) | |||
| Warranty (years) | 5 | |||
| Communication | ||||
| Communication interfaces | RS485; RS232 | |||
| Monitoring | GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional) | |||
| String intelligent monitoring | Optional | |||
| Certifications | ||||
| Certifications and standards | IEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2 | |||
| Grid codes | IEC 61727; IEC 62116; CEI 0-21; EN 50549; NRS 097; RD 140; UNE 217002; OVE-Richtlinie R25; G99; VDE-AR-N 4105 | |||
Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.
Downloads
Applications
Works with
SUN-60-75K-G01P3-EU-AM8-LV
60 – 75 kWThree-phaseIP65
View details
SUN-70-110K-G03
70 – 110 kWThree-phaseIP65
View details
G6-GC(80-150)K
80 – 150 kWThree-phaseIP66
View details
Request a quotation
You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.