WIT 29.9-50K-XHU Hybrid inverter

WIT 29.9-50K-XHU

Hybrid inverter · Three-phase · 29.9 – 50 kW

29.9 – 50 kWThree-phaseIP66
Price on request
29.9 – 50 kWRated power
Three-phasePhase
4MPPT trackers
98.1 %Max. efficiency

Technical data

WIT 29.9K-XHUWIT 30K-XHUWIT 36K-XHUWIT 40K-XHUWIT 50K-XHU
PV input
Max. PV input power (W)59800600007200080000100000
Max. PV input voltage (V)1100
Rated PV input voltage (V)620
MPPT voltage range (V)180 – 1000
Start-up voltage (V)195
Max. input current per MPPT (A)40
Max. short-circuit current per MPPT (A)50
Number of MPPT trackers4
PV strings per MPPT2
Max. open-circuit voltage of PV (V)1000
Full-load DC voltage range (V)375 – 850375 – 850450 – 850500 – 850620 – 850
AC output
Rated output power (W)2990030000360004000050000
Max. apparent power (VA)2990033000396004400055000
Rated AC voltage (V)400
PhaseThree-phase
Rated AC frequency (Hz)50/60
Max. AC output current (A)45.3506066.783.3
Power factor>0.99 (at nominal power); adjustable -1 to +1
Total harmonic distortion (THDi) (%)<3
Backup output power (W)2990030000360004000050000
Peak (surge) power (W)4485045000540006000075000
Generator inputYes
Max. parallel units10
Nominal AC voltage and range (grid)380/400 V, -15% to +10%
AC grid connection type3P3W+PE / 3P4W+PE
Nominal AC grid frequency range (50 Hz / 60 Hz) (Hz)45-55 / 55-65
AC input nominal power (grid) (W)59800600007200080000100000
Max. AC input apparent power (grid) (VA)59800660007920088000110000
Max. AC input current (grid) (A)90.6100120133.3166.7
Max. input current (GEN / AC coupling) (A)90.6 / 45.3100 / 45.5120 / 54.5133.3 / 60.7166.7 / 75.7
Max. continuous AC passthrough current (A)200
Backup: Max. AC apparent power (VA)2990045000540006000075000
Backup: Nominal AC voltage220/230 V (L-N); 380/400 V (L-L)
Backup: Nominal AC frequency (Hz)50/60
Backup: Max. output current (A)68.068.281.891113.6
Backup: Overload capability1.5 x rated power, 10 s
Backup: THDv (linear full load) (%)<3
Backup: On/off-grid switchover time<=10 ms
Backup: Unbalanced load capability100% three-phase unbalanced
Battery
Battery voltage range (V)200 – 900
Full-load battery voltage range (V)200 – 800200 – 800225 – 800250 – 800310 – 800
Recommended battery voltage (V)512
Number of battery inputs3
Max. charge/discharge current per battery input (A)55
BMS communicationRS485 / CAN
Efficiency
Max. efficiency (%)98.1
Protection
Protection functionsDC reverse polarity protection; Battery reverse protection; Insulation resistance monitoring; AC/DC surge protection (Type II); AC short-circuit protection; Ground fault monitoring; Grid monitoring; String monitoring; Anti-islanding protection; Residual-current monitoring unit
General data
Dimensions (W x H x D) (mm)920 × 585 × 320
Weight (kg)90
Ingress protection (IP rating)IP66
Operating temperature range (°C)−30 – 60
Relative humidity (%)0 – 95
Max. operating altitude (m)4000
CoolingSmart air cooling
Noise level (dB)≤55
TopologyTransformerless
Warranty (years)5 – 10
UPS functionYes
Black start functionYes
Smart load functionYes
Weak-grid adaptability (short-circuit ratio, SCR)<1.2
Communication
DisplayOLED + LED; app
Communication interfacesRS485; USB; CAN; Wi-Fi (optional); LAN (optional)
Certifications
Certifications and standardsIEC/EN 61000-6-1; IEC/EN 61000-6-3; IEC/EN 62109-1; IEC/EN 62109-2
Grid codesNRS 097-2-1:2017; EN 50549-1; NC RFG; PSE-2018; PTPiREE-2021; IEC 62116; IEC 61727; G99:2020; VDE 4105

Values from the manufacturer's datasheet, pending final confirmation. The datasheet supplied with the product prevails.

Downloads

Datasheets

User manuals

  • WIT 29.9-50K-XHU user manual (English) (3)PDF · 2.2 MBDownload
  • WIT 29.9-50K-XHU user manual (English) (4)PDF · 2.2 MBDownload

Applications

Works with

Request a quotation

You receive the datasheet, certificates, tiered pricing from your target quantity and a shipping date.

Fields marked * are required.

One working day reply. Your details are used for this quote only. How we handle your data: Privacy

Price on request Get a quote